EasyManua.ls Logo

ActronAir PRV15AT-TVFT-EV User Manual

ActronAir PRV15AT-TVFT-EV
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Variable Capacity Commercial (R-32 Series)
Inverter Package Ducted Units
Installation and Commissioning Guide
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
That’s better. That’s Actron.
Model Numbers
PRV15AT-TFFT-EV*
PRV17AT-TFFT-EV*
PRV15AT-TVFT-EV
PRV17AT-TVFT-EV
Under/Over Unit
*
Front discharge Air Handling Option shown
for illustration purposes only.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ActronAir PRV15AT-TVFT-EV and is the answer not in the manual?

ActronAir PRV15AT-TVFT-EV Specifications

General IconGeneral
BrandActronAir
ModelPRV15AT-TVFT-EV
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Instructions

Hazardous Voltage - Risk of Electrocution

Emphasizes turning off power, observing LOCK-OUT/TAG-OUT procedures, and risks of severe injury or death.

Beware of Rotating Fans !

Warns to ensure fans are stopped before servicing and to avoid pinch points and sharp edges.

Installation Information

Recover and Recycle Refrigerants

Details procedures for recovering, recycling, and handling refrigerants responsibly and safely.

Refrigerant Handling and Safety

Consults MSDS for proper handling, health, safety, storage, and disposal requirements.

Handling R-32 Refrigerant

Highlights R-32's mild flammability and specific handling requirements by licensed technicians.

Wiring Configuration : Recommended

Wiring Configuration : Alternate

Electrical Control Panel

Compressor Variable Speed Drive (VSD) Assembly

Service Clearances, Airflow Allowances and Weights

Unit Lifting Procedure

Crane Lifting Method

Outlines the safe procedure for lifting the unit using a crane, including equipment needed.

Fork Lift Method

Details the safe procedure for lifting and moving the unit using a forklift.

Outdoor Unit Preparation

Electrical Installation

Wiring Diagram and Connections

Directs users to the internal wiring diagram for correct electrical connections.

Supply and Power Requirements Procedure

Details power supply compatibility, protection, earthing, and voltage balance requirements.

Electrical Connection

Circuit Breaker Size and Cable Size Recommendation

Recommended Breaker and Cable Sizes

Provides a table with recommended circuit breaker sizes and cable sizes for different models.

Wiring Connections

Configuring and Commissioning Setup

Configuring Compressor and Capacity (cnFg)

Details how to configure compressor type and capacity settings.

Configuring Control Source (CtrS)

Details setting the control source for BMS, third-party, or wall controls.

Demand Response Management

Third Party Control Input

0-10V Analogue Control Inputs

Explains how to use 0-10V analogue inputs for controlling fan and compressor via third-party systems.

Run and Fault Indication Output

Remote On/Off Control

Indoor Fan Commissioning

Refrigerant Charging

Charging Method: Subcooling & Superheat

Details the subcooling and superheat method for accurate refrigerant charging.

Final Charge Recording

Guides on recording the final refrigerant charge on the unit and in reports.

Charging Pressure/Temperature Table

Provides a table of pressure and temperature values for charging calculations.

Maintenance

Maintenance Procedures & Safety

Outlines general maintenance procedures, safety precautions, and required PPE.