Indicator LED State Fault Condition Comments to User
Off (No water flow) No Fault -
Off (Water flow)
The unit is not powered
Verify that the unit is connected to power
and that the input voltage is within
specifications (11-16V).
The flow direction is
reversed
Ensure the inlet and outlet tubes are
connected to the respective fittings
marked “IN” and “OUT” on the device.
The flow rate is too low
The flow sensor inside the unit requires a
minimal water flow to activate the system
(approx. 0.3 L/min≈0.08 Gallons/min).
Ensure there is enough water pressure
(i.e. 12 PSI) in the line to reach this flow.
Red UV-LED fault
Unplug and plug in the device’s power
jack. If this fault persists, contact Acuva
for support.
Yellow Blinking Low input voltage
Verify that the input voltage is above 11
volts.