B. LOCATION REQUIREMENTS
The tilt model dryer requires 18-inches (45.72 cm) on the right side of the dryer for ease of service. For the
left side clearance on a 1 door dryer is 18-inches (45.72 cm), and for a 2 door dryer 36-inches (91.44 cm) is
required due to the side exhaust. The rear of the dryer requires a 36-inch (91.44 cm) clearance for ease of
service. Refer to the chart below for ceiling height requirement for each of the tilting dryer models.
The dryer must be leveled for proper operation. If shimming is required, place 11-inch x 10-inch (27.94 cm
x 25.4 cm) metal shims under the base feet. The dryer must be lagged to the floor.
Gas
WARNING: Dryer should be located where a minimum length of exhaust duct will be necessary.
310 TILT CLEARANCE ALLOWANCE
Dryer Style Ceiling Height Requirement
310 1 Door / Forward Tilt
310 1 Door / 2-Way Tilt
310 2 Door / Rear Tilt
133-inches
133-inches
133-inches
337.82 cm
337.82 cm
337.82 cm
Shaded area is stated in metric equivalents