48
SECTION VIII
BURNER and BASKET (TUMBLER)/LINT CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
IMPORTANT
MANUAL RESET HI-LIMIT INSTRUCTIONS
PHASE 7
(GAS MODELS ONLY)
This dryer was manufactured with a burner manual reset hi-limit and basket (tumbler)/lint chamber hi-limit
thermostat. If either burner manual reset hi-limit thermostat is open prior to the start of the drying cycle, or
during the cycle, the dryer will recognize the open state of the burner hi-limit thermostat and display a hi-limit
fault. The manual reset hi-limit thermostat must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner
oven operation.
The location of the manual reset hi-limit switch is on the left side of the burner box and the tumbler hi-limit
is located in the lint chamber area.
WARNING: Discontinue power to the dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N: 114093