8 American Dryer Corp. 113546-2
Installation Procedures _______________
Installation should be performed by competent professional
in accordance with local, state, and country codes. In the
absence of these codes, the installation must conform to
applicable American National Standards: ANSI Z223.1-
LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA
NO. 70-LATEST EDITION (National Electrical Code) or in
Canada, the installation must conform to applicable Canadian
Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/
CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General
Installation and Gas Plumbing) or Canadian Electrical Codes
Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for
Electrical Connections).
Location Requirements _______________
Before installing the dryer, be sure the location conforms to
local, state, and country codes. In the absence of such codes
or ordinances the location must conform with the National Fuel
Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the
installation must conform to applicable Canadian Standards:
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-
M91 (L.P. Gas) or LATEST EDITION (for General Installation
and Gas Plumbing).
The dryer must be installed on a sound level floor capable of
supporting its weight. Carpeting must be removed from the
floor area that the dryer is to rest on.
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
Provisions for adequate air supply must be provided as noted
in this manual (refer to Fresh Air Supply Requirements
section).
Clearance provisions must be made from combustible
construction as noted in this manual (refer to Dryer Enclosure
Requirements section).
Provisions must be made for adequate clearances for servicing
and for operation as noted in this manual (refer to Dryer
Enclosure Requirements section).
The dryer must be installed with a proper exhaust duct
connection to the outside as noted in this manual (refer to
Exhaust Requirements section).
The dryer must be located in an area where correct exhaust
venting can be achieved as noted in this manual (refer to
Exhaust Requirements section).
IMPORTANT: The dryer should be located where a
minimum amount of exhaust ducting will be necessary.
The dryer must be installed with adequate clearance for air
openings into the combustion chamber.
CAUTION: This dryer produces combustible lint and
must be exhausted to the outdoors. Every 6 months,
inspect the exhaust ducting and remove any lint
buildup.
IMPORTANT: The dryer must be installed in a location/
environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).
Illus. No. Description
1 Microprocessor Control/Keypad Panel Assembly (controls)
2 Control (top access) Door Assembly
3 Main Door Assembly
4 Lint Door Assembly
5 Outer Top
6 Wire Diagram (located behind control door)
7 Top Console (module) Assembly
8 Upper Back Guard
9 Lower Back Guard
10 Rear Electrical Box Cover
Dryer Rear View
Component Identification ____________
Dryer Front View
Illus. No. Description
1 Tumbler Drive Motor Assembly
2 Blower Motor Mount Assembly
3 Blower Motor (impellor/fan) Assembly
4 VFD - Blower Motor (optional)
5 Tumbler Bearing Mount Assembly
6* Electric Service Relay Box
7 Heating Unit
8 Rating Plate
9 Water Connection - S.A.F.E. System (optional)
10 Gas Connection
11 VFD - Tumbler Drive Motor
* Electric service connections are made in this box.