ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-58
© 2000, ADC Telecommunications, Inc.
DLP-516
Page 3 of 6
5170-C
CONFIGURATION SWITCHES
(COMPONENT SIDE VIEW)
DEFAULT SWITCH SETTINGS : 6, 5, 4 - ON, 3, 2, 1 - OFF
654321
ON
654321
ON
SWITCH
6
5
4
3,2,1
FUNCTION
LOOP POWER
UNUSED
LOOP 2
LINE LENGTH 3 2 1
0 - 133 FT OFF OFF OFF
133 - 266 FT OFF OFF ON
266 - 399 FT OFF ON OFF
399 - 533 FT OFF ON ON
533 - 655 FT ON OFF OFF
POSITION
ON (ENABLED)
OFF (DISABLED)
ON (ENABLED)
OFF (DISABLED)
Figure 516-1. Version C HLXC Module Configuration Switches

Table of Contents