OSCILLOSCOPE
Step 5. Set Calibrator at -24 dB point.
Adjust VR805 (left) for -12 dB on left LED Meter.
And VR806 (right) for -12 dB on right LED Meter.
Both LED's should be lit. (Figure 10C)
Step 6. Set Calibrator at -25 dB point, check that both -12 dB on left and right LED have
turned off. (Figure 10D)
Step
7.
Set Calibrator at -12 dB point.
Adjust VR803 (left) for 0 dB on left rED Meter.
And VR804 (right) for 0 dB on right LED Meter.
Both LED's should be lit. (Figure 10E)
Step
8.
Set Calibrator at -13 dB point.
Checkfor both OdB points. Left and right LED haveturned off. (Figure 10F)
Step
9.
RepeatSteps3 through 8 for optimum performance.
NOTE: Refer to Check Point for eachLED Meter below:
CHECK POINT FOR EACH LED METERS
(SeeFigure 10 and Figure 10A through 10F.)
LED Meter point
-12 -10 -8
-6
-4
-2
0
+2 +4
+6 +8 +10 +12
dB
dB
dB
dB dB dB
dB dB
dB dB dB
dB dB
Calibrator position for
-24 -22 -20 -18 -16 -14
-12 -10
-8 -6 -4
-2
0
eachLED that is lit.
dB
dB dB dB dB dB
dB dB dB dB
dB dB dB
Calibrator position for
-25 -23
-21
-19 -17 -15 -13 -11
-9 -7 -5 -3
-1
eachLED that isnot lit.
dB dB dB dB dB dB
dB dB dB dB
dB dB dB
r- --------------------,
e
I
I
CALIBRATION
I
I
I
(dB ATTENUATORl
SS-3
r-r-r--
f-o
I
I
®
=
c::=
AC
V.
T.VM
I
I
iHmm~~
D
~~i~ii~m~
I
-6 -18
I~I
(0
I
-4 20
I
-2
0
-22
@--~
888888888888
e
@888888888888:
c::: ~
o
-24
"
r'
INPUT OUTPUT
IOKO
AUDIO
Figure 10
LOAD
OSCILLATOR
1~lo-
7fr
NOTE:
r---
OUTPUT TERMINALS ON SET SHOULD BE CONNECTED TO
10 Kn
LOAD.
------
AC VTVM.
,-----------1
CALIBRATOR
1
(dB ATTENUATORl
I
I
I
1
I
1
1
I
I
1
I
(-24dB POINT)
1
L
_j
Figure 10C
1------------'
1
CALIBRATOR
i
1
(dB ATTENUATORl I
1 I
1
-10ElE!l_14
I
I
_6-@-'~'"
I
1
-4
-20
I
1
-2 -22
I
I
0
-24
1
I
I
I
(-12 dB POINT)
1
L
J
Figure 10E
--------------------~
,----------------,
i
CALIBRATOR I
I
(dB ATTENUATORl
I
I I
I 1
i
_;@_10-'2-14-,~,"
II
-4 -20
-2 -22
I
~ -24
I
,-----------'
I
CALIBRATOR
I
I
(dB ATTENUATORl
I
I I
i
_6-@"_10-12_14_16_
,
"i
I
-4 -20
I
I I
I ~
-22
I
I
0 -24
I
I I
1
0
I
I
(-ldB POINT)
I
L
_j
Figure 10 B
-10 -12 -14
-6-@"_16_
,s
-4 -20
-2 -22
o
E24dBi
AC VT.V.M.
L_
_:_O~':·~8.::~~~O~~~
_j
Figure 10A
-15-
r
I
I
I
I
I
I
I
1
I
I
I I
I
(-25dB POINT)
I
L
__J
Figure 100
,---------,--,
I
CALIBRATOR
I
I
(dB ATTENUATORl
I
I I
I _s@_,O
-t~_16
i
I
-6 -IS
1
1
-4 -20
I
I
-2 -22
I
I
0
-24
1
I
I
L__
~-~d~~~~ __
J
Figure 10 F
------l
CALIBRATOR
I
(dB ATTENUATORl
I
I
I
I
I
I
I
I

Table of Contents

Related product manuals