K3635V2 7/03 Rev. B
$'(0&2%'9
7:2:$<:,5(/(66.(< :,7+92,&( 67$786
INSTALLATION INSTRUCTIONS
General Information
The 5804BDV is a four-button wireless key that permits the
user to control the alarm system remotely. It is a two-way
device that can send a command to the alarm system, such
as to arm or disarm, as well as receive status back.
Status is indicated by two bi-color status LEDs and a
piezoelectric sounder. Each button can be programmed for
any zone response type, but is typically used for arming,
disarming, panic, and output relay operation.
1. The 5804BDV must be used in conjunction with
one of the following:
x
5800TM (Transmitter Module) and a 5881or
5881EN*receiver.
x
6128RF receiver.
x
Lynx control panel.
2.
Place the 5881 or 5881EN receiver and the
5800TM Transmitter Module in a high, centrally
located area for best reception. The 5800TM
module must be located between 1 and 2 feet
from the receiver.
*Must be used to activate High-Security mode.
The unit is powered by 2 replaceable Lithium batteries
designed to provide up to 2 years of life. These batteries are
supplied with the unit but not installed (see “To Install/Replace
Batteries” for more information).
5804BDV-001-V0
5804BDV Front View
Red/Yellow
LED
Green/Yellow
LED
Button A
Button C
Button D
Button B
Belt Clip
Loop Assignments:
x
Button A =>Loop 3
x
Button B =>Loop 2
x
Button C =>Loop 4
x
Button D =>Loop 1
Note
:
To Remove or Insert the Unit from Belt Clip
5404BDV-002-V0
To Install / Replace Batteries
1. Remove the screw from the case back.
2. Remove case back by using the blade of a small
screwdriver to pry open.
3. Place batteries in case back locations (see diagram). Use
CR2430 or DL2430 Lithium battery only.
4. Close the case by snapping case front and back
together.
5.
Replace the screw to secure the case.
WARNING!
Improperly installing the batteries will cause
damage to the batteries
.
Programming the 5804BDV House ID
You must program a House ID number into the unit before
you can use it to display the system status.
The House ID
number must be same as the one used in the alarm
control.
The House ID must be in the range of 01 to 31. The
default in the 5804BDV is 10.
To Enter a House ID
1. Enter House ID mode by pressing the
A
,
B
, and
C
buttons at the same time until the Red and Green LEDs
alternate flashing.
2. Enter the House ID number by using the
A
button to
enter the 10s digit and the
B
button to enter the 1s
digit.
Note:
If the entry is out of range (greater than 31),
the unit will discard the entry.
3. Accept the entry by pressing the
D
button.
4. The unit displays the stored number by flashing the left
LED for the 10s
digit and flashing the right LED for the
1s digit (for example, for House ID 21, the left LED will
flash twice, the right LED will flash once).
5. The unit will then exit the House ID mode.
Example:
To enter House ID # 17 into the unit:
5804BDV-004-V0
4321
HID will be shown
by flashing LEDs.
Then exit HID mode.
To accept entry,
press D button.
Enter HID #17: Press
& release A button
once, press & release
B button 7 times.
Enter HID mode:
Press A +B + C
buttons until LEDs
flash.