165 Eileen Way, Syosset, New York 11791
Copyright © 1998 Pittway Corporation
àN6481V2]ä
N6481V2 5/98
N6481V2 5/98
®
5807
SMOKE DETECTOR
with BUILT-IN
WIRELESS TRANSMITTER
INSTALLATION INSTRUCTIONS
For use with QED control panels ONLY!
GENERAL INFORMATION
The Ademco No. 5807 Photoelectric Smoke Detector/Transmitter is intended for
use with wireless alarm systems that support QED 5800 series devices, and
contains a built-in transmitter which can send alarm, supervisory and battery
condition messages to the system's QED receiver/control unit. Refer to the
wireless system's instructions for the maximum number of transmitters that can
be supported.
Alarms: The smoke detector is powered by two 9-volt batteries and will sound
its built-in horn when smoke reaches the detector (and the LED indicator will light
steadily). A message will also be sent to the wireless QED control and the smoke
detector's ID number will be displayed at the console. The alarm message will be
transmitted every 4 seconds, until the smoke condition has cleared and the
detector has reset. After the horn has stopped, a Restore message will be
transmitted to the QED control and it will then be possible to clear the ID number
from the display. During normal or low battery conditions, the LED indicator will
flash about once every 7 seconds.
Low Battery: The detector indicates a low battery condition by emitting a "beep"
about once every 15 seconds. A low battery message will be sent to the QED
control unit upon any transmission following the first battery beep (with the
detector's ID number displayed at the console). The battery should be replaced
within 7 days following the low battery signals.
Programming: Note that the QED control system must “enroll” the smoke
detector’s ID during installation of the system. The QED control should be
programmed to “enroll” the 5807 as an “RF” type unit (i.e., supervised RF). See
the
PROGRAMMING
section in this instruction book and the QED control unit’s
Installation Instructions for further details.
PRESS
TEST
TEST BUTTON
RELEASE TAB
POWER ON/ALARM
INDICATOR
Figure 1. 5807 Smoke Detector
Question and Answer IconNeed help?

Do you have a question about the ADEMCO 5807 and is the answer not in the manual?

ADEMCO 5807 Specifications

General IconGeneral
BrandADEMCO
Model5807
CategorySmoke Alarm
LanguageEnglish

Summary

GENERAL INFORMATION

Detector Operation Modes

Explains alarm, low battery, and normal operation indications including horn, LED, and messages.

System Programming Requirement

Notes the need to "enroll" the 5807 as an "RF" type unit via the QED control system.

INSTALLATION PROCEDURES

Battery and Bracket Installation

Covers installing two 9-volt batteries correctly and attaching the mounting bracket securely.

Mounting Location Guidance

Details finding the best location and selecting suitable mounting spots for optimal performance.

TESTING AND MAINTENANCE

Wireless Transmission Path Test

Procedure to ensure good RF signal reception from the proposed location before permanent installation.

Detector Mounting and Testing

Covers attaching the detector to the bracket and performing post-installation operational tests.

Battery Replacement Procedure

Instructions for replacing batteries, including timing, type, and post-replacement checks.

SPECIFICATIONS AND RECOMMENDATIONS

Technical Specifications

Lists key technical details like power source, sensitivity, operating temperature, and dimensions.

NFPA Installation Standards

Outlines National Fire Protection Association recommendations for smoke detector placement in residences.

Recommended & Avoided Locations

Provides guidance on ideal and unsuitable locations for detector installation to prevent nuisance alarms.

LIMITATIONS AND SAFETY

Detector Limitations

Discusses limitations of the detector and system, including factors affecting performance and fire protection.

Environmental Operating Limits

Notes operating limits for temperature and issues with insect infestations causing nuisance alarms.