freeingthe o~rator from the task of silencingthe No. 685.
ti the
event of a cmputer faflureor a switchto the ~UAL mo&, the alert
tone will ~ triggeredfor al messages.
NOTS: If the ‘PulseRelayn option (SeeSectionVI B 8) has been
chosen,the rmote ~ert relay will activatefor 2 seconds
on ALL messages. This will ~low a remote~ert sounderto
be used at the computerconsolewhfle reservingthe intern~
alertsoonderfor systemmessagesofiy.
6.
Selection of ~~sr out~ f-s for &2 ness~:
When a b-2
message is received,the computeroutput will normallybe in 4-2,
which is:
RG AC~ EI
where R is Receivernumber
G is the line card Groupor rotarynumber
AC~ is the Accountnmbsr
E is an Eventcode
I is the Zoneidentifier
In order to interfaceto the AdemcoCAPS commter system,an optional
outputformat,CAPS4-2,is reqti”red.It is:
RG AC~ DDDA
-
where
DDD is a 3-digitdecim~ numkr in the range O-255
A is an ASCII‘Aw character
me valueof DDD is calctiatedas follows:
DDD = (16 x Eventcode)+ Zone identifier
For Hex event males,the follwing nombrs sre used:
B=ll, c=12, D=13, E= 14, F=15
~smple: InWt Message= 12 3456 F4
DDD = 16x 15 (F) = 240 4 =244
The m-sa~
12 3456244A wodd b sent.
To select the CAPS output fomat, check tox 7 in PROM CRART 7 and
follw the programmingprocedurein SectionVI C steps34 --37.
In addition,the standardcodesfor openingand &osing by user (BO-
BF ad CO
- W respectively)must be translatedto AdemcoHI speedfor
the CAPS system. Whenevera 4-2 code be~nning withB is received,an
opening remrt is sent.
The user # will be set to matti the mne
identifierof the message.
-
Users are encouragedto use codesB and C for openand close. For
56