PREPARATION OF THE MACHINE
The machine unpainted parts are protected with a factory-applied ultra-fine oily film. It is not
necessary to remove it before using the machine. However, if you wish you can remove it, use a
cloth soaked spirit. Wipe and clean and then apply a sliding agent (Sliber-gleit, Molycote, etc.).
WORKING CONDITIONS
The machine is intended for work under the roof if the following conditions are fulfilled.
Air temperature: from 5
0
C to 40
0
C, relative humidity: from 30% to 95% non-condensing, altitude
above sea level: max 1000m.
The machine must be used as a stationary tool.
ELECTRICAL CONNECTION
WARNING! Before connection to the mains, check that the mains voltage corresponds with the
characteristics of the machine supplied.
Use a 1.5 mm2 (min.) supply cable with strengthened insulation, (e.g.HO7). If the length of the
cable from the meter to the machine exceeds 10 meters, use 2.5mm2 (min) cable. The internal
connections (motor, switch, coil, etc.) are factory wired.
SINGLE PHASE 230V CONNECTION: This connection should be made with a 3 core cable
and a standard 16A two pole + earth plug. Two wires are provided for the supply (L1, L2) and
the third (yellow/green) must be connected to the earth.
THREE PHASE 380V CONNECTION: This connection should be made with a 4 core cable and