EasyManuals Logo

adept technology SmartController CX User Manual

Default Icon
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
MP6 to sMI6 Cables
Adept SmartMotion Installation Guide, Rev. B 51
Table 4-2 shows the pinout for the cable that connects between the XMACHINE connector
on the sMI6 module and the MP6-M panel.
Table 4-2. Pinout for MP6-M
sMI6 Pin
MP6-M
Pin Signal sMI6 Pin
MP6-M
Pin Signal
1 8 26 OT4+
1 2 OT1+ 9 27 OT4–
3 3 OT1– 23 28 HM4+
17 4 HM1+ 24 29 HM4–
18 5 HM1– 38 30 BR4+
32 6 BR1+ 39 31 BR4–
33 7 BR1– 32
4 8 OT2+ 33
5 9 OT2– 34
19 10 HM2+ 10 35 OT5+
20 11 HM2– 11 36 OT5–
34 12 BR2+ 25 37 HM5+
35 13 BR2– 26 38 HM5–
6 14OT3+ 40 39BR5+
7 15OT3 41 40BR5
21 16 HM3+ 12 41 OT6+
22 17 HM3– 14 42 OT6–
36 18 BR3+ 27 43 HM6+
37 19 BR3– 29 44 HM6–
20 42 45 BR6+
21 44 46 BR6–
22 47
23 48
15 24 HPE+ 16 49 SP2+
30 25 HPE– 31 50 SP2–
Shell Shell Shield