EasyManua.ls Logo

ADF LINEA 100 - Installation and Technical Specifications; Technical Specifications

ADF LINEA 100
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
2- Installation Instructions
Technical Specifications
Antonino Dias Fernandes Lda., declares under its responsibility that the equipment has been designed and manufactured
according to (EU Reg. No. 305/2011), Construction Products Regulation, being approved with the CE conformity mark;
Uni.
70
100
85
Duo
100
Duo
kW
8,1
10,4
8,4
9,8
%
84
80
78
75
Vol.%
0,05
0,09
0,11
0,12
ºC
238
286
267
300
g/s
6,0
7,8
6,9
8,2
Pa
12
mm
180
200
200
200
mm
1500
mm
530
830
630
830
kg
4
6
5
6
kg
135*
180*
170*
204*
Apenas Lenha com humidade inferior a 20%
* “box” weight only
Note:
The compartment below the combustion chamber of the freestanding appliances should not be used as a fuel tank.
Freestanding heaters shall be laid on a non-combustible non-flammable surface (if it is stone or other equivalent at least
6cm high) where the ends extend at least 80cm from the front of the appliance.
.

Other manuals for ADF LINEA 100