storage. Setting NAMESERVER
may conflict with DHCP
which acquires NAMESERVER
automatically. Do not set NAMESERVER
when DHCP
for IP1
is active.
DHCP - Enables your device to extract an IP Address from a DHCP server for use as the
Ethernet IPA for the IP 1 port. The overall purpose of this is to reduce the work necessary
for administration of a large IP network. Consult your Network Administrator before using
DHCP. This setting requires the presence of a DHCP server on the LAN. The DHCP server
needs to be able to notify a DNS server of the IP address associated with the unit name
(which is the Device Name).
IP Address - The Internet Protocol (IP) Address used for the IP # port of the device. The
device's IP address must adhere to certain standards and not conflict with the IP address of
any another device on the network. IP address(es) with 0 or 255 in them are invalid. Please
consult your organization's Network Administrator before assigning an IP address to a unit.
An IP address of 0.0.0.0 can be assigned and will effectively disable the unit's network
capabilities.
Subnet Mask - The Subnet Mask sets the network subnet mask assigned to the unit.
Consult your organization's Network Administrator for the IP Subnet mask for your unit(s).
MAC Address - Displays the units physical MAC address.
Link Status - Displays whether the connector detect link or not.
Link Speed - Displays the connected link speed if the link is up.
NTP Address - NTP Address is the IP address of an external source for time. It should be
entered in decimal form XXX.XXX.XXX.XXX . Setting the NTP Address to 0.0.0.0 turns NTP
off.
Time Zone - Time Zone is used to specify the name of your timezone, the offset is in hours
from UTC and a Daylight Savings Setting.
Date - This field will auto-populate if your device is networked to an NTP server; it can also
be used to manually designate a time-of-day for timekeeping and internal scheduling.
Time - This field will auto-populate if your device is networked to an NTP server; it can also
be used to manually designate a time-of-day for timekeeping and internal scheduling.
SNMP - Controls the status (ON/OFF) of the Simple Network Management Protocol (SNMP)
feature. We support SNMPv2c version.
Read Only Community - The Simple Network Management Protocol (SNMP) Read-Only
Password. Default Value: "adtec"
Read Write Community - The Simple Network Management Protocol (SNMP) Read-Write
Password. Default Value: "none"
75