What to do if small amount of solution or no solution reaches the brush of my Advance acoustic Adfinity 17ST?
- JJustin CarterAug 17, 2025
If the Advance acoustic Floor Machine isn't dispensing enough solution or any at all, several factors could be at play. The solution/clean water filter might be clogged and needs cleaning. Inspect the solution/clean water tap to ensure it isn't stuck closed; if it is, replace it. Check the solenoid valve for damage or wiring issues, replacing the valve or repairing the connection as needed. Also, verify that the solution tank and hoses are free of debris; clean them if necessary.