Type | Depth Sounder |
---|---|
Display | LCD |
Output Signal | NMEA0183 |
Housing Material | Plastic |
Protection Rating | IP67 |
Accuracy | ±1% |
Describes the S400 unit's display features, readability, and screen treatment against condensation.
Lists standard items included with the Depth S400 unit, such as protective cover, user manual, and warranty card.
Details sounder measurement range, accuracy, resolution, and battery voltage specifications.
Specifies the buzzer output capabilities, including voltage and current limits, and fuse recommendation.
Details NMEA 0183 interface version, baud rate, data format, and proprietary frame.
Describes the Half-Duplex 38400 baud communication bus link and device connection limit.
States the required power supply voltage range (9-16.5V) and consumption.
Provides the unit's physical size (112x112x28mm) and flush mounting details.
Specifies the IP66 rating for the front panel and IP40 for the rear panel.
Defines the acceptable operational temperature range from -10°C to +50°C.
Specifies the temperature range for storing the unit, from -20°C to +60°C.
Explains how to power the Depth S400 unit, noting it has no integrated switch.
Details how to operate the unit in its standard functional mode.
Describes using the up/down keys to cycle through displayed data like depth and battery voltage.
Explains how to change units for depth (Feet/Metres) and battery voltage (V) using keys.
Details how to activate and use the countdown timer function, including its signals.
Explains how to adjust the display and key backlighting levels from 0 to 4.
Describes how alarms are indicated (icon, flashing) and triggered by thresholds.
Guides users on setting high and low alarm thresholds for depth readings via menu.
Explains how to configure the low threshold for the battery voltage alarm via menu.
Introduces the configuration menu and how data values are displayed during changes.
Explains how to set the keel offset for accurate depth measurement from the hull.
Details how to set the duration for the countdown timer feature between 1 and 10 minutes.
Describes the simulation mode for sales demos and its functions like displaying profiles and data.
Explains how to activate or deactivate the audible key beep feature.
Details how to restore factory settings for various parameters like unit, offset, and alarms.
Explains how to put the unit into standby mode to save energy by pressing the key.
Describes connecting and operating the unit on the AdvanSea AS-1 bus for data exchange.
Explains how repeater vs. measurement instruments display data on the bus, prioritizing serial numbers.
Details how repeater instruments can read/write parameters like calibration via the AS-1 bus.
Lists event messages like Err Bat, Err MEM, and Err Bus and their causes and disappearance.
Covers NMEA 0183 input and output interfaces, compliance, and data formats.
Explains how the NMEA 0183 input acquires data and uses priority management for frames.
Describes the NMEA 0183 output emitting depth data (DPT, DBT) at 1 Hz.
Provides guidance on physically mounting the Depth S400 unit and its connections.
Details placement requirements, protection from shocks, and mounting surface considerations.
Details the wiring for bus connection and sounder sensor connection.
Explains the 7-wire shielded cable connections for the bus (Red, Black, Orange, etc.).
Describes the connection to the sounder sensor via a 30 cm coaxial cable with RCA connector.
Summarizes the main connection steps for sounder, power, and NMEA sources.
Lists common causes for the unit failing to power on, like blown fuses or low voltage.
Provides reasons for incorrect depth readings, including sensor issues, interference, and environment.
Addresses the issue of 'SIMU' flashing, indicating the unit is in simulation mode.