- 10 -
www.advateklights.com PixLite A4-S Mk3 User Manual V211013
5 - Electrical Connections
5.1 - Supplying Power
Power is applied to the PixLite A4-S Mk3 via the large lever clamp connector. The
levers should be lifted up for wire insertion and then clamped back down, providing a
highly robust and secure connection. Ensure the wire’s insulation is stripped back 11-
12mm, so that the clamp does not rest on the insulation when closing the connector.
Polarity for the connector is clearly marked on the top surface, as shown in Figure 6
below. The type of wire required for supply connection is 4.0mm
2
, 10AWG, VW-1.
Refer to Section 9.2 for operating specifications for powering this device.
Note: It is the user’s responsibility to ensure that the power supply used matches the
voltage of the pixel fixture they are using and that it can supply the correct amount of
power/current.
Figure 6: Location of Power Input
5.2 - Smart Electronic Fuses & Power Injection
Each of the 4 pixel outputs are protected by a Smart Electronic Fuse. The functionality
of this fuse type is similar to a physical fuse, where the fuse will trip if the current goes
above a specified value, however with smart electronic fusing, the fuse does not