EN - 24 -
BEFORE CALLING YOUR AFTER SALES SERVICE PART - 6.
If you are experiencing a problem with your freezer, please check the following before
contacting the after-sales service.
Your freezer is not operating
Check if:
• There is power
• The plug is correctly placed in the socket
• The plug fuse or the mains fuse has blown
• The socket is faulty. Examine this by plugging your freezer into a working socket.
A rise in the temperature may be caused by:
• Opening the doors frequently for long periods of time
• Loading the appliance with large quantities of warm foods
• A high ambient temperature
• An error with the appliance.
Your freezer is operating noisily
Normal noises
Cracking (ice cracking) noise occurs:
• During automatic defrosting
• When the appliance is cooled or warmed (due to expansion of appliance material).
Short cracking noise occurs: When the thermoat switches the compressor on/o.
Motor noise: Indicates the compressor is operating normally. The compressor may
cause more noise for a short time when it is r activated.
Bubbling noise and splash occurs: Due to the ow of the refrigerant in the tubes of
the syem.
Errors
Your freezer will warn you if the temperatures for the freezer are at improper levels or if a
problem occurs with the appliance. Warning codes are displayed in the freezer indicators.
ERROR TYPE MEANING WHY WHAT TO DO
E01
Sensor warning
Call Service for assistance as
soon as possible.
E02
E03
E06
E07
E08 Low Voltage Warning
Power supply to the device
has dropped to below
170 V.
- This is not a device failure, this
error helps to prevent damages
to the compressor.
- The voltage needs to be
increased back to required
levels
If this warning continues an
authorised technician needs to be
contacted.