8.4 Cleaning the drain
Periodically clean the drain hole to
prevent water from overflowing and
dripping onto the stored bottles. The
drain hole is located in the lower left part
of the appliance.
Before cleaning, remove the two bottom
shelves. For cleaning purpose, use a soft
tube cleaner.
Refer to the "Removing and
installing shelves" chapter
for instructions on how to
remove and install the
shelves.
8.5 Periods of non-operation
When the appliance is not in use for long
periods, take the following precautions:
1. Disconnect the appliance from
electricity supply.
2. Remove all items.
3. Clean the appliance and all
accessories.
4. Leave the door open to prevent
unpleasant smells.
When the appliance is not in use due to
power failure:
Most power failures are corrected
within a few hours and don't affect the
temperature of your appliance if you
minimize the door opening.
If the power is going to be off for a
longer time, you need to take the
proper steps described above.
9. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
9.1 What to do if...
Problem Possible cause Solution
The appliance does not op‐
erate.
The appliance is switched
off.
Switch on the appliance.
The mains plug is not con‐
nected to the mains socket
correctly.
Connect the mains plug to the
mains socket correctly.
There is no voltage in the
mains socket.
Connect a different electrical
appliance to the mains socket,
to check if electricity is flowing.
If not, contact a qualified elec‐
trician.