TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Work-contacting element does not depress
fully - tool does not operate.
Nails are low.
Work-contacting element is jammed.
Replenish the nails.
Remove the battery and clear the debris.
Tool operates properly, but fasteners are not
driven fully.
Air pressure is too low.
Depth of drive is not deep enough.
Nail is too long for wood hardness.
Increase the air pressure.
Adjust the depth of drive.
Use nails of the length that is appropriate for
the wood.
Tool operates properly, but fasteners are driven
too deep.
Air pressure is too high.
Depth of drive is too deep.
Decrease the air pressure.
Adjust the depth of drive.
Tool jams frequently. Nails are incorrect.
Nails are damaged.
Magazine is loose.
Magazine is dirty.
Verify that the size of nails is correct.
Replace the nails.
Tighten the screws.
Clean the magazine.
Tool stops and LED work lights flash rapidly. Battery is low or has no charge.
Tool is hot.
Recharge the battery.
Allow tool to cool.
Tool has charged battery and LED work lights
flash slowly.
Tool has malfunctioned. Take tool to the nearest authorised repair
centre.