4.2 NON-washable activated charcoal
lter - The saturation of the charcoal lter
occurs after more or less prolonged use,
depending on the type of cooking and the
regularity of cleaning of the grease lter.
In any case it is necessary to replace the
cartridge at least every four mounths.
regenerated.
The carbon lter must be regenerated every
two months (or when the lter saturation indica-
tor - if present - indicates the need for it) and in
accordance with the procedure as shown here
below:
1. Disconnect the electrical appliance from the
mains.
2. Clean the lter’s surface with a damp cloth
to remove grease deposits.
3. Put the lter in an oven at 200 degrees for
45 minutes.
4. Turn off the oven and wait for an hour
before taking out the lter.
Attention! Make sure the lter has cooled
down before touching it.