1.3
Safety
Instructions
AN
The
unit
must
not
be
operated
in
rooms
where
there
is
a
risk
of
fire
or
explosion
due
to
chemicals,
dust,
gases
or
fumes;
be
operated
in
the
immediate
vicinity
of
pipes
or
containers
which
carry
or
contain
inflammable
or
explosive
substances;
-
be
operated
when
the
minimum
distances
from
adjacent
object
surfaces
are
not
kept.
e
This
unit
must
only
be
installed
(electrical
installation),
commissioned
and
maintained
by
an
authorised
expert
according
to
these
instructions.
e
The
unit
must
on
no
account
be
operated
when
work
on
floors
such
as
laying,
sanding,
sealing,
cleaning
with
petrol
and
caring
(spray,
wax)
and
similar
is
being
performed.
Then
the
room
must
be
adequately
aired
before
charging.
e
The
heater's
casing
surfaces
and
the
air
outlet
grille
can
heat
up
to
temperatures
above
80
°C.
Therefore
no
inflammable,
ignitable
or
heat
insulating
objects
or
materials
such
as
washing,
blankets,
newspapers,
containers
of
floor
wax
or
petrol,
aerosol
cans
and
similar
may
be
placed
on
or
in
the
immediate
vicinity
of
the
heater.
Washing
must
never
be
hung
over
the
heater
to
dry.
Danger
of
catching
fire!
e
The
following
minimum
distances
must
be
kept
from
the
heater
by
all
kinds
of
objects,
e.g.
furniture,
curtains
and
textiles
or
other
flammable
and
non-flammable
materials
especially
from
the
air
outlet
grid
(fig.
2):
to
the
air
outlet
grille
=>
500mm
from
the
right
side
wall
(for
installation
clearance)
>
100
mm
from
the
left
side
wall
>
70
mm
from
the
left
side wall
with
two
storage
heaters
next
to
one
another
=
100mm
from
the
cover
(e.
g.
window
ledge)
>
40
mm
from
the
cover
(curtains,
inflammable
materials)
=>
100mm
The
hot
air
must
be
able
to
discharge
unhindered
(fig.
19)!
e
The
label
enclosed
with
these
operating
and
installation
instructions
"Do
not
place
objects
on
or
lean
them
against
the
heater"
must
be
affixed
well
visibly
on
the
top
of
the
heater
in
commercially
used
rooms
such
as
hotels,
holiday
homes,
schools
etc.
1.4
Care
and
Maintenance
If
slight
brown
discoloration
of
the
unit
housing
should
occur,
this
should
be
rubbed
off
immediately
with
a
soft
cloth.
The
device
should
be
cleaned
cold
with
normal
cleaners.
Abrasive
and
aggressive
cleaners
should
be
avoided.
Do
not
spray
cleaning
spray
into
the
air
vents.
The
ventilation
duct
behind
the
air
outlet
grille
(5)
should
be
checked
by
a
specialist
every
two
years.
Slight
dirt
deposits
may
accumulate
here.
We
recommend
that
you
have
the
inspection
and
control
elements
checked
during
regular
maintenance.
Safety,
inspection
and
control
elements
as
well
as
the
entire
charging
and
discharge
control
system
should
be
checked
by
a
specialist
10
years
after
first
commissioning
at
the
latest.
\
1.4.1
Cleaning
the
Fluff
Screen
(fig.
3)
The
fluff
screen
(7)
located
in
the
air
inlet
grille
(6)
must
be
cleaned
regularly,
so
that
fault-free
discharging
of
the
storage
heater
is
guaranteed.
The
fans
switch
off
when
the
fluff
screen
is
blocked.
Proceed
as
follows
to
clean
the
fluff
screen.
Press
the
air
inlet
grille
(6}
down
slightly
on
both
sides,
tip
forward
at
the
front
and
remove;
-
Press
the
fluff
screen
out
of
the
grille
with
a
screwdriver
for
example
and
clean
with
a
brush,
vacuum
cleaner
or
similar;
Replace
the
fluff
screen
in
the
grille
and
snap
in
the
lugs.
-
Place
the
air
inlet
grille
at
an
angle
on
the
lugs
in
the
unit
base
and
snap
in
under
the
air
outlet
grille
by
pressing
lightly
(fig.
16).