1.
Operating
Instructions
1.1
Technical
Description
Storage
heaters
store
electrically
generated
heat
during
low-cost
electricity
tariff
periods
(depending
on
the
electricity
supply
company,
mainly
during
the
night
hours).
This
is
then
discharged
according
to
the
desired
room
temperature
as
hot
air
by
a
fan
and
to
a
small
extent
through
the
surface
of
the
heater.
1.2
Operation
.
The
unit
is
operated
by
the
control
panel
(1)
on
the
right
side
wall
(fig.
1).
1.2.1
Heat
Storage
The
degree
of
heat
storage
(charging)
is
determined
by
the
selector
knob
(fig.
17).
A
distinction
needs
to
be
made
here
between
operation
of
the
storage
heater
with
or
without
central
weather-controlled
charging
control
unit
(is
in
the
sub-distributor).
If
there
is
no
central,
weather-controlled
charging
control
unit
[manual
operation,
fig.
18),
the
selector
knob
should
be
set
as
follows:
è
=
no
charging
1
=Transitional
period
(Spring/Autumn)
-
corresponds
to
about
1/3
full
charge
2
=
Mild
Winter
days
-
corresponds
to
about
2/3
full
charge
3
=
Winter
days
-
corresponds
to
full
charge
After
a
short
while
you
will
soon
have
the
necessary
experience
to
find
the
right
setting
every
time.
If
there
is
a
central,
weather-controlled
charging
control
unit
(automatic
operation),
the
selector
knob
should
be
set
to
position
3.
The
weather-controlled
charging
control
unit
then
takes
care
of
the
right
charging.
For
varying
control
of
individual
storage
heaters,
the
charging
volume
can
be
adapted
manually
with
the
selector
knob
even
when
a
charging
control
unit
is
available.
1.2.2
Heat
Discharge
The
heat
discharge
is
controlled
by
a
wall-mounted
or
integrated
AEG
room
temperature
regulator
(special
accessory).
The
desired
room
temperature
must
be
set
at
the
room
temperature
regulator
which
then
controls
the
heat
discharge
automatically
with
the fan
so
that
the
set
room
temperature
is
kept
constant.
On
very
cold
days
it is
advisable
to
leave
the
room
temperature
regulator
switched
on
during
long
periods
of
absence
(several
days)
to
keep
the
temperature
at
about
10
°C
for
example
so
that
the
building
or
room
does
not
go
cold
(protection
against
frost).
21