A
What
to
do
when
...?
Keep
these
instructions
in
a
safe
place,
pass
on
to
the
new
owner
in
case
of
a
change
of
ownership.
Make
them
available
to
the
specialist
in
the
case
of
repair
work.
For
the
User
For
the
specialist
e
the
storage
heater
does
not
get
hot
e
the
storage
heater
housing
should
get
extraordinarily
hot
even
in
mild
weather
Check
whether
.
.
.
-
the
selector
knob
is
set
to
position
3.
.
the
corresponding
fuses
in
`
your
fuse
box
are
defective
or
the
Fl
switch
has
switched
off.
Eliminate
the
cause!
If
the
following
day
the
storage
heaters
have
still
not
heated
up,
call
a
specialist.
Check
whether...
...
the
fan
can
be
switched
on
with
the
room
temperature
regulator.
If
not,
call
a
specialist.
.
the
fluff
screen
in
the
air
inlet
grille
is
blocked.
Eliminate
cause
as
described
in
section
1.4.1!
Check
whether
...
...
the
control
of
the
heating
element
contactor
is
OK.
.
there
is
a
voltage
at
terminals
L1/L2/L3.
.
whether
the
safety
temperature
limiter
(F1)
has
triggered.
"CLIC"
Check
whether
...
...
the
room
temperature
regulator
has
switched
on
and
voltage
is
applied
at
terminal
LE.
.
the
fans
are
turning.
.
the
safety
temperature
regulator
"(N5,
see
page
3,
fig.
1)
in
the
air
outlet
has
switched
off.
.
the
control
signal
Z1
of
the
charging
control
unit
is
applied
at
terminal
A1/Z1
in
the
storage
heater.