Unit that detects
initiates an alarm.
The LED flashes green once
every second for 5 seconds.
None.
Alarm cancellation: When the
smoke concentration level
drops below the alarm
threshold, the alarm signal
will stop. Then, the alarm
goes back to the standby
mode.
Test
unit.
The LED flashes red 3 times
every 4 seconds.
every 4 seconds.
Press the test/silence button.
interconnected
units.
The LED indicator flashes red
rapidly.
Continuous
beeping until
you release the
test/silence
button.
Initiating unit.
Hold down the test/silence
button on one unit in the
network.
green sequentially.
Other interconnected alarms
in the network.
Silence Mode
Red LED flashes once every 5
seconds.
None.
After 9 minutes, the unit will
exit silence mode.
Low Battery
Red LED flashes once every
60 seconds.
1 beep every 60
seconds.
independent warning.
Malfunction
Red LED flashes twice every
40 seconds.
2 beeps every 40
seconds.
independent warning.
Alarm Mode
The X-SENSE wireless interlinked alarms can be interconnected such that any unit that senses danger will
cause all other units in the interconnected network to alarm.
1. If the Initiating Unit Is Triggered by Smoke:
When one smoke alarm is triggered in the interconnected network, the unit will beep 3 times, paired with
the LED that flashes red every 4 seconds. Any other interlinked units will follow suit—they will beep 3
times every 4 seconds, paired with the LED flashing red and green in succession.