2. If the Initiating Unit Is Triggered by CO:
When one CO alarm is triggered in the interconnected network, the unit will beep 4 times every 5.8
seconds, paired with the LED flashing red. Any other interlinked units in the network will follow
suit—they will beep 4 times every 5.8 seconds, paired with the LED that flashes red 4 times first, followed
by the LED that flashes green once with every beep. When the CO concentration level drops below the
alarm threshold, the alarm will cease.
NOTES
When one unit is triggered, other interconnected units will sound. If the smoke alarm and CO
alarm are triggered in the network at the same time, the alarm signal of the smoke alarm will take
priority over that of the CO alarm.
This alarm has a relay function that extends the wireless interconnected network for wide detection
coverage.
Silence Mode
If you press the silence button during an alarm state, the unit will be in the silence mode for 9 minutes.
During the silence mode, the LED will flash red once every 5 seconds. The alarm will enter the normal
mode after 9 minutes.
NOTES
You can silence all interconnected units by pressing the test/silence button on one of the units. If
one unit is still alarming, it is the initiating unit (the unit that detected danger); to silence all
interlinked units, you must also press the test/silence button on the initiating unit.
While interconnected, the initiating unit cannot be triggered again during the 9-minute silence
duration. However, all other interconnected units can be triggered again if they detect danger
during the silence mode.
Technical Specifications
Power Supply Replaceable 3 V CR123A lithium battery
Operating Life 10 years