1.6
(1) DB 27°C - WB 19°C DB 35°C - WB 24°C
(2) DB 20°C - WB 15°C DB 7°C - WB 6°C
DB 35°C - WB 24°C DB 43°C - WB 32°C
DB 18°C DB -5°C
DB 27°C DB 24°C - WB 18°C
DB 5°C DB -10°C
M.E. CMP23I
kW 2.35
kW 2.36
W 730
W 720
l/h 1.1
V-F-Hz 230-1-50
W/W
3.22
W/W 3.28
A+
A
No. 4
mm 1030x555x170
kg 48.5
dB(A) 27/41
mm 162
R-410A
g 520
W 1060 *
A 4.8 *
MPa 3.8
IPX0
E
N
USER MANUAL
Please read data plate to obtain the technical data listed
below.
- Power supply voltage
- Maximum absorbed power
- Maximum absorbed current
- Amount of refrigerant gas
- Casing protection level
- Max. working pressure
Technical data
** Noise pressure measured 1 m away and 1.5 m high Relevant regulation EN 14511. 1. 2.3.4
Room t External t
Cooling mode tests
Heating mode tests
Internal ambient temp. Outside ambient temp.
Maximum operating temperature in cooling mode
Minimum operating temperature in cooling mode
Maximum operating temperatures in heating
Minimum operating temperatures in heating
Operating limits
Refer conditions
Technical data
Cooling power (1)
Heating power (2)
Power absorbed when cooling (1)
Power absorbed when heating (2)
Dehumidification capacity
Power supply voltage
EER
COP
Energy efficiency ratio when cooling
Energy efficiency ration when heating
Internal-external ventilation speed
Dimensions (WxHxD)
Weight
Noise level (min-max) **
Wall holes diameter
Refrigerant gas
R410A refrigerant charge
Maximum absorbed power
Maximum absorbed current
Maximum working pressure PS
Casing protection level
* with Dual Power function activated during heating