250FS 350FS 500FS
WRCA • • •
CC2*
• • •
Legend
• Compatible
– Not compatible
* The accessory CC2 version 01 is compatible with the indoor units of the MLG_FS serie, from version 01.
ACCESSORIES
TECHNICAL DATA
12
MLG250FS MLG350FS MLG500FS
Nominal cooling performances
Cooling capacity (1)
kW 2,70 3,50 5,20
Moisture removed
l/h 0,8 1,2 3,8
Nominal heating performances
Heating capacity (2)
kW 2,80 3,75 5,33
Electric data
Rated power input (3)
W 50 50 50
Indoor unit
Type of fan
Type Centrifugo inverter
Air ow rate
Minimum
m³/h 280 360 320
Maximum
m³/h 430 520 650
Sound power
Minimum
dB(A) 38,0 41,0 45,0
Maximum
dB(A) 48,0 50,0 55,0
Sound pressure (4)
Minimum
dB(A) 26,0 31,0 35,0
Maximum
dB(A) 36,0 40,0 45,0
Indoor unit
Condensate Discharge Diameter
mm 28,0 28,0 28,0
Diameter of liquid refrigerant
connections
mm (inch) 6,35 (1/4”) 6,35 (1/4”) 6,35 (1/4”)
Diameter of refrigerant gas
connections
mm (inch) 9,52 (3/8”) 9,52 (3/8”) 12,7 (1/2”)
Power supply
Indoor unit power supply
220-240V ~ 50Hz
(1) Cooling (EN-14511 and EN-14825) ambient air temperature 27 °C D.B. / 19 °C W.B.; outside air temperature 35 °C; max speed; length of refrigerant lines 5 m.
(2) Heating (EN-14511 and EN-14825) ambient air temperature 20 °C D.B.; outside air temperature 7 °C D.B. / 6 °C W.B.; max speed; length of refrigerant lines 5 m.
(3) The rated power input (rated current input) is the maximum input electrical power (maximum current input) from the system, in accordance with the Standards
EN-60335-1 and EN-60335-2-40.
(4) Sound pressure measured in semi anechoic chamber at a distance of 1,5 m from the source.