C-10 Subject to Export Control, see Cover Page for details.
C-4. REMOTE OPERATION COMMANDS (cont)
AGC
COMMAND RANGE DESCRIPTION
:agc:mode 0 - Manual
1 - Auto
Sets AGC Mode.
:agc:mode? Returns AGC Mode.
:agc:rfamp_mode 0 - Auto
1 - OFF
2 - ON
Sets Receiver input preamp state.
:agc:rfamp_mode? Returns Receiver input preamp state.
:agc:state Activates Receiver AGC.
:agc:state? Returns Receiver AGC state.
:agc:tos -90.0 to 10.0 dBm Sets Top of Scale adjustment for Manual AGC
Mode.
:agc:tos? Returns Top of Scale adjustment for Manual AGC
Mode.