1-12 Subject to Export Control, see Cover Page for details.
1-3. EQUIPMENT DATA (cont)
OSCILLOSCOPE (OPTIONAL)
Single Input Channels: ............................................................ DVM, Audio In, Internal Demod
Input Impedance:
DVM Input: ............................................................................................................ 1 MΩ
Audio I/O Input: .................................................................... 150 Ω , 600 Ω , High Z (3500)
150 Ω , 600 Ω , 1 KΩ, Divide-by-10, High Z (3500A)
Coupling:
DVM Input: ........................................................................................... AC, DC and GND
Audio I/O Input: ........................................................................................................ AC
FM Internal Demod: ................................................................................................... DC
AC Internal Demod: ................................................................................................... AC
Range:
DVM and Audio I/O Output: ................................ 10 mV/Div to 10 V/Div in a 1,2,5 sequence
FM Internal Demodulation: ............................ 0.1 kHz/Div to 50 kHz/Div in a 1,2,5 sequence
AM Internal Demodulation: ........................................................... 5%, 10%, 20%, 50%/Div
Vertical Accuracy: ................................................................ 10% of Full Scale (DC to 5 kHz)
Bandwidth: ............................................................................................................... 5 kHz
Horizontal Sweep:
Range: ...................................................................................... 0.5 ms/Div to 0.1 sec/Div
Accuracy: .............................................................................................. 3% of Full Scale
Trigger Source: .......................................................................... Auto or Normal (Internal)
Trigger Adjustment: .................................................................. Variable on Vertical Scale
Markers: ..................................................................................................... Two Markers
Displays Vertical Measurement (Voltage, kHz, % Modulation)
Displays Delta in Time between Markers
SPECTRUM ANALYZER (OPTIONAL)
Frequency:
Range: ................................................................................................... 2 MHz to 1 GHz
Span: ....................................................................... 10 kHz to 5 MHz in a 1,2,5 sequence
Windows: ................................................................................. Hanning, Flat Top, Rectangle
Vertical Scale: .................................................................................. 2, 5, 10, 15, 20 dB/Div
Marker Range: ................................................................ 1 kHz to 5 MHz in a 1,2,5 sequence
Marker Offset: ........................................................... ±1 kHz to 0.5 Span in a 1,2,5 sequence
Power Bandwidth Accuracy: ........................................... ±3 dB Typical (30 dB Signal to Noise)
Noise Floor: ................................................................. ±3 dB Typical (30 dB Signal to Noise)