TETRA MS Remote Commands
Subject to Export Control, see Cover Page for details.
5 - 63
5.22.3 Tx Burst Power - Limit Value
:LIMits:TXMeas:POWer:VALue:xxx
:LIMits:TXMeas:POWer:VALue:xxx?
5.22.4 Tx Burst Timing - Limit Enable
:LIMits:TXMeas:BTIMing:ENABle:xxx
:LIMits:TXMeas:BTIMing:ENABle:xxx?
Description: Set command defines Limit for Tx Burst Power Measurements for specified
burst type.
Query command returns parameter setting.
Range: -9.9 to +9.9 dB
Units: dB
Default Values:
Default/Normal:
Highest Power Level Upper: +2.0 dB
Highest Power Level Lower: -2.0 dB
Other Power Level Upper: +2.5 dB
Other Power Level Lower: -2.5 dB
Extreme:
Highest Power Level Upper: +3.0 dB
Highest Power Level Lower: -4.0 dB
Other Power Level Upper: +4.0 dB
Other Power Level Lower: -4.0dB
Set/Query Format: NRf | NR2
Burst Type (xxx): CONTrol | NORMal | CW
Example: :LIMits:TXMeas:POWer:VALue:NORMal 3,-3,5,-5
Sets Limit for Normal Tx Burst Power Measurements to the following:
Highest Power Level Upper: +3.0 dB
Highest Power Level Lower: -3.0 dB
Other Power Level Upper: +5.0 dB
Other Power Level Lower: -5.0 dB
Query Response: :LIMits:TXMeas:POWer:VALue:NORMal?
3.0,-3.0,5.0,-5.0
Description: Set command Enables/Disables Limit for Tx Burst Timing Measurements for
specified burst type.
Query command returns parameter setting.
Parameter: OFF | ON | 0 | 1
Default Values:
Default/Normal: ON
Extreme: OFF
Set/Query Format: Boolean
Burst Type (xxx): CONTrol | NORMal
Example: :LIMits:TXMeas:BTIMing:ENABle:NORMal ON
Enables Limit for Normal burst Tx Burst Timing Measurements.
Query Response: :LIMits:TXMeas:BTIMing:ENABle:NORMal?