Installation and Operation Manual
On-Grid PV Inverter

Questions and Answers

  • M
    Melissa BarronSep 7, 2025
    How to resolve IntProtectK error on Afore BNT020KTL Inverter?
    • J
      James McclainSep 7, 2025
      If your Afore Inverter displays IntProtectK, it indicates a bus over voltage protection issue. Ensure the AC output wiring is well connected and uses stranded copper cable.
  • H
    hollanddennisAug 22, 2025
    What to do if my Afore BNT020KTL Inverter shows GFCI.Err?
    • G
      glennneilAug 22, 2025
      If your Afore Inverter displays a GFCI.Err message, it indicates a ground leakage current is high or the PV(+) or PV(-) is earthed. To resolve this, first check the AC output wiring and restart the inverter. If the issue persists, inspect the PV array wiring.
  • N
    Nicole SmithSep 5, 2025
    What to do for IntFaultK or IntFaultM error on Afore Inverter?
    • S
      Sarah MurphySep 5, 2025
      If your Afore Inverter displays IntFaultK or IntFaultM, it indicates a bus voltage fault. Here's what you should do: 1. Ensure the AC output wiring is well connected and uses stranded copper cable. 2. Verify that the PV array configuration is correct. 3. Check that the voltage difference between BUS+ and BUS- is not too high.
  • D
    douglastylerSep 3, 2025
    What causes IntProtectQ on my Afore Inverter?
    • T
      Tammy EvansSep 3, 2025
      If your Afore Inverter displays IntProtectQ, it indicates DCI protection. Check that the PV array configuration is correct. Also, verify that the voltage difference between BUS+ and BUS- is not too high.
  • M
    Michael GilmoreSep 2, 2025
    How do I resolve IntFaultG error on my Afore Inverter?
    • B
      Bruce NelsonSep 2, 2025
      If your Afore Inverter displays IntFaultG, it indicates a high DCI. Check that each PV array's configuration is correct and verify that the voltage difference between BUS+ and BUS- is not too high.
  • T
    Tony JohnsonAug 31, 2025
    What does IntProtectP mean on Afore BNT020KTL Inverter?
    • C
      Christopher MartinezAug 31, 2025
      If your Afore Inverter displays IntProtectP, it indicates a frequency fault protection. When the grid frequency returns to normal, the inverter will restart automatically.
  • S
    Sherry BrownAug 30, 2025
    How to fix IntFaultB on Afore Inverter?
    • E
      Erika PerryAug 30, 2025
      If your Afore Inverter displays IntFaultB, it means the bus voltage is out of range. Check that the PV input voltage does not exceed 900Vdc per channel and ensure the AC output wiring is well connected.
  • K
    Kim MichaelAug 29, 2025
    What does IntProtectN error mean on my Afore BNT020KTL?
    • A
      Angela NelsonAug 29, 2025
      If your Afore Inverter displays IntProtectN, it means there is an inverter over current protection. When grid conditions return to normal, the inverter will restart automatically.
  • C
    Chelsea PriceAug 27, 2025
    What does IntFaultD mean on my Afore BNT020KTL?
    • D
      Diana StevensAug 27, 2025
      If your Afore Inverter displays IntFaultD, it indicates a software over current fault. Check that the PV array configuration is correct. If there are fluctuations on the grid, wait for it to return to normal; the inverter will restart automatically.
  • T
    Toni WilliamsAug 27, 2025
    What causes IntFaultE on my Afore Inverter?
    • M
      Megan JonesAug 27, 2025
      If your Afore Inverter shows IntFaultE, it indicates an over current fault. The inverter will automatically restart once the grid returns to normal.

Summary

Safety & Symbols

Installation

Installation Steps

Outlines the sequential process for installing the PV inverter.

Electrical Connection

PV Connection

Details the procedure and requirements for connecting PV strings.

Grid Connection

Describes how to connect the inverter to the AC grid.

Operation

Startup Setting

Guides through the initial configuration process after installation.

Parameter Setting

Details how to adjust and configure inverter operational parameters.

Commissioning

Commissioning Procedures

Lists steps to follow before and during system startup.

Shut Down & Restart

Maintenance & Troubleshooting

Fault Code and Troubleshooting List

Provides error codes and corrective actions.

Afore BNT020KTL Specifications

General IconGeneral
Max. DC Voltage1100 V
MPPT Voltage Range200-1000 V
Number of MPPTs2
AC Voltage Range310 - 480 V
THDI< 3%
AC Grid Frequency50 / 60 Hz
Max. Efficiency98.6%
DC ConnectionMC4
Protection DegreeIP65
Weight32 kg
Nominal AC Power20000 W
Max. AC Power22000 W
Nominal AC Voltage400 V
Power Factor0.8 leading - 0.8 lagging
Operating Temperature Range-25°C to +60°C