140 OUTPUT 705; "TRIG:SOUR TIM"
150 END
Line 10: Selects channel 1 and turns the input off.
Line 20: Selects the CV mode.
Line 30: Sets the main voltage level to 5 volts.
Line 40: Sets the transient voltage level to 10 volts and the voltage slew rate to maximum.
Line 50: Selects toggled transient operation.
Line 60: Enables transient operation and turns on the channel 1 input.
Line 70: Selects channel 2 and turns the input off.
Line 80: Selects the CV mode.
Line 90: Sets the main voltage level to 10 volts.
Line 100: Sets the transient voltage level to 20 volts and the slew to maximum.
Line 110: Selects toggled transient operation.
Line 120: Enables transient operation and turns on the channel 2 input.
Line 130: Sets the internal trigger oscillator frequency to 2 kHz (period of pulses = 0.0005).
line 140: Selects the Multiple Electronic Load’s internal oscillator as the trigger source. The oscillator running as soon
as this line is executed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 6050A and is the answer not in the manual?

Agilent Technologies 6050A Specifications

General IconGeneral
BrandAgilent Technologies
Model6050A
CategoryComputer Hardware
LanguageEnglish

Related product manuals