Adapted from HP Service Sheet “D WB0SMX
8640b Gear Set Replacement
DESCRIPTION
• A9, Peak Deviation and Range Switch Assembly
A9 REMOVAL AND DISASSEMBLY PROCEDURE
1. Set PEAK DEVIATION and RANGE switches fully ccw.
2. Remove PEAK DEVIATION and RANGE switch knobs. The knobs are secure
with allen screws in the knobs.
3. Place instrument upside down and remove bottom cover (see Service Sheet
G).
Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8640b and is the answer not in the manual?

Agilent Technologies 8640b Specifications

General IconGeneral
Frequency Resolution1 Hz
Power Resolution0.1 dB
Output Impedance50 Ohms
Modulation TypesAM, FM
Harmonics-30 dBc
Spurious-70 dBc
Dimensions425 mm x 132 mm x 420 mm
AM Modulation0-100%