1-138 Chapter1
Alphabetical Command Reference
MARK
MARKFAUV Sets the auxiliary value of the fixed
marker position. Works in coordination
with
MARKFVAL and MARKFSTI.
amplitude range
3
<num><
L
F
>
MARKFSTI Sets the stimulus position of the fixed
marker.
stimulus range
1
<num><
L
F
>
MARKFVAL Sets the value of the fixed marker
position.
amplitude range
3
<num><
L
F
>
MARKMAXI
Same as
SEAMAX (search for maximum on
current channel's trace).
N/A
<0|1><
L
F
>
MARKMIDD Makes the marker amplitude the limit
segment middle value during a limit
segment edit.
N/A N/A
MARKMINI
Same as
SEAMIN (search for minimum on
current channel's trace).
N/A
<0|1><
L
F
>
MARKOFF Turns all markers and marker functions
off.
N/A
<0|1><
L
F
>
MARKREF Sets the reference value to that of the
active marker's amplitude.
N/A N/A
MARKSPAN Sets the span for the entire trace to that of
the span between the active marker and
the delta reference marker.
N/A N/A
MARKSTAR Sets the start stimulus to that of the
active marker's.
N/A N/A
MARKSTIM During a limit segment edit, sets the limit
stimulus break point to that of the active
marker's.
N/A N/A
MARKSTOP Sets the stop stimulus to that of the active
marker's.
N/A N/A
MARKUNCO Uncouples the markers between channels,
as opposed to
MARKCOUP.
N/A
<0|1><
L
F
>
MARKZERO Places the fixed marker at the active
marker position and makes it the delta
reference.
N/A N/A
1. For frequency or power sweeps, refer to “Preset State and Memory Allocation, in your analyzer’s reference guide.
For CW time: 0 to 24 hours. For frequency sweep, transform on: ±1/frequency step. For CW time sweep, transform
on: ±1/time step.
2. For example, on a 201 point sweep, <num> can range from 0 to 200.
3. For log mag: ± 500 dB. For phase: ± 500 degrees. For Smith chart and Polar: ± 500 units.
For linear magnitude: ± 500 units. For SWR: ± 500 units. The scale is always positive, and has minimum
values of 0.001dB, 10e12 degrees, 10e15 seconds, and 10 picounits.
Command Description Range Query
Response

Table of Contents

Other manuals for Agilent Technologies 8719ES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8719ES and is the answer not in the manual?

Agilent Technologies 8719ES Specifications

General IconGeneral
BrandAgilent Technologies
Model8719ES
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals