3
Option 014
configurable test set
Adds SMA connectors on front panel for access
to various source output and receiver input sig-
nal paths, including direct access to receivers.
When jumpers are in place, the analyzer per-
forms like a standard 8753ES except that maxi-
mum source output power is reduced by 2 dB.
Do not order Option 014 with Option 011 or 075.
This option is not available as an upgrade kit, it
must be purchased at time of initial instrument
order.
Option 075
75-ohm impedance
Replaces the standard 50 ohm test set with
a 75 ohm test set. Test ports are 75-ohm type-N
female connectors. Do not order Option 075
with Option 006, 011, or 014.
Option 1D5
High-stability frequency reference
Provides improved frequency accuracy over time
and with temperature variation.
The following special options are available to cus-
tomize the 8753ES for particular applications.
Please contact Agilent for a quote on these options,
to obtain information on expected instrument per-
formance, or to request other special configurations.
Option H16
low noise floor
Adds switches that allow the port 2 coupler
to be reversed, so that the forward transmitted
signal travels along the through path in the
coupler instead of the coupled path, increasing
the forward dynamic range by about 12 dB while
decreasing the dynamic range in the reverse
direction by about 15 dB.
Option H39
three-port test set
Test set has an added coupler and switching
to provide three 50-ohm type-N female test
ports for measuring all nine S-parameters of
a three-port device.
Option H68
6.8 GHz operation
Extends operation to 6.8 GHz. Performance
above 6 GHz is not specified (typical only).
Option H85
high-power test set
Provides jumpers to allow the user to add an
external power amplifier to provide up to 20
watts (+43 dBm) of power at the test ports, and
high-power attenuators or isolators for higher
input power handling. The standard solid-state
transfer switch is replaced by a mechanical
transfer switch to handle higher output power,
and step attenuators are added between the
couplers and samplers to prevent receiver over-
load. Test ports are 3.5 mm, and the start
frequency of this test set is 50 MHz.

Other manuals for Agilent Technologies 8753ET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8753ET and is the answer not in the manual?

Agilent Technologies 8753ET Specifications

General IconGeneral
BrandAgilent Technologies
Model8753ET
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals