CYLINDER CONTAINER SIZE: A self contained LP-gas cylinder for use with this appliance must
have a capacity of 20 lbs. and must be equipped with a Type I connector and
an OPD (overfill protection device).
The LP-gas supply cylinder to be used must be constructed and marked in accordance with the
specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT) or the National
Standard of Canada CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of
Dangerous Goods.
- The cylinder supply system must be arranged for vapor withdrawal.
- The cylinder used must include a collar to protect the cylinder valve.
- This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a
building, garage or any other enclosed space.
- When this appliance is not in use, the gas must be turned off at the supply cylinder.
- Storage of this appliance indoors is permissible only if the cylinder is disconnected and removed
from the appliance.
- Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.
Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored
in a building, garage or any other enclosed area.
The item is approved for installation on combustible floors.
CSA (Canadian Standards Association) certified to CSA International Requirement
4.96 U.S. ( 3rd Edition) “Outdoor Gas Fireplaces” and CR97-003 “Outdoor Gas Fireplaces”.
TYPE 1 CONNECTOR
INPUT 40,000 Btu/hr High Fire 30,000 Btu/hr Low Fire
Propane Regulator Pressure 11 inches water column
Natural Gas Inlet Pressure 7 inches water column
Clearances to combustible surfaces: Sides 24 in. / 60.0cm Top 72 in. / 182.8cm
IMPORTANT SAFETY INFORMATION ABOUT PROPANE (LP) GAS