pg 14
Electrical continued...
m OPEN INPUT: Any device that is used to open the
gate from a closed position is an open input device. The
device used must provide normally open contacts. These
normally open contacts are connected to terminals 4 and 5.
These open input terminals will cause the gate operator to
open and/or close.
m STOP INPUT: Any device that is used to stop the
gate operator while it is running in the open or closed direc-
tions is a stop input device. These stop input devices must
provide normally open contacts. To connect these normally
open contacts, use terminals 7 and 8. Stop input may also be
used for simple external safety devices which can be used to
stop the gate when there is a vehicle or a pedestrian present.
When the gate operator is told to stop using the stop input, the
gate will remain stopped until it is told again to run using the
open input.
TO AVOID POSSIBLE INJURY OR
DAMAGE TO EQUIPMENT
DO NOT MAKE ELECTRICAL
CONNECTIONS WHILE POWER
IS ON
7
ACCESSORY CONNECTIONS
STANDARD CAPABILITY