Electrical continued...
m OPEN INPUT: Any device that is used to open the
gate from a closed position is an open input device. The
device used must provide normally open contacts. These
normally open contacts are connected to terminals 5 and 6.
These open input terminals will cause the gate operator to
open and/or close if the timer switch is in the OFF position. If
the timer switch is in the ON position, these open input
terminals will cause the gate operator to open and will hold the
gate open until the input is released and the hold open time
has elapsed.
m CLOSE INPUT: Any device that is used to close the
gate is a close input device. The device used must provide
normally open contacts. These normally open contacts are
connected to terminals 9 and 10. These close input terminals
will cause the gate operator to close the gate any time the
gate is in a non-closed position and can be used to override
the timer and close the gate prematurely.
m N.C. STOP INPUT: Any device that is used to stop
the gate operator while it is running in the open or closed
directions is a stop input device. These stop input devices
must provide normally closed contacts. To connect these
normally closed contacts, remove the stop jumper from
terminals 8 and 9 and then connect the contacts to these
same terminals 8 and 9.
m N.O. STOP INPUT: This input functions identical to
N.C. Stop with the exception that it requires normally open
contacts. These contacts are connected to terminals 9 and 11.
m SAFETY INPUT: Any device that is used to open and/
or hold open the gate while the gate is in a non-closed
position is a safety input device. The safety input device
must provide normally open contacts. These contacts are
connected to terminals 4 and 6. This function is especially
useful when the auto close timer is being used in prevent-
ing the gate from accidentally closing on a pedestrian or
vehicle.
m PULSE OPEN INPUT: The pulse open input
terminals were put on the circuit board as an alternative
connection for the radio receiver. This input functions
similarly to the standard open input with the exception that
it will not hold the gate open if the input remains present.
This feature will add additional security to the gate operator
system in the event that there is a transmitter that is stuck
on. Pulse open is found at terminals 6 and 7.
8
ACCESSORY CONNECTIONS
FULL SYSTEMS CAPABILITY
TO AVOID POSSIBLE INJURY OR
DAMAGE TO EQUIPMENT
DO NOT MAKE ELECTRICAL
CONNECTIONS WHILE POWER
IS ON