EasyManuals Logo

Aiphone GF Series User Manual

Aiphone GF Series
6 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
10
9
System components
Entrance station
Apartment station Concierge Control units Power supply
.
Packet of screws
.
OPERATION MANUAL
GF-1DK
w/panic call
GF-1D
.
Packe t of screws
.
OPERATION MANUAL
GF-1MDK
w/panic call
GF-1MD
Power supply
PS-2410LC
(AC 120V)
PS-2410LD
(AC 230V)
MAW-B
Relay for
entrance light
(option)
W-DIN11
Mounting rail for
GF-BC, VBC & 4Z
(option)
Front frame & back box
2/3-module front frame
.
Mounting bracket
.
Packet of screws
.
Weather stripping
(for reinforcement)
GF-2F(3F)
OPTION
Call switch Module
Audio Module Camera Module
Address panel
GF-AP
Address module
.
Directory card
(plate & paper)
.
Connnector
GF-AD
Blank panel
GF-BP
GF-H
Rain hood
GF-C
80cm connecting wire
GF-HB
Hooded surface mount box
.
Available for either 2-and 3-module Panels in 1, 2 and 3 rows.
< Digital name scrolling module >
GF-NSP GF-10KP
GF-NS
Digital name scroll module
.
Connnector
.
OPERATION MANUAL
GF-10K
Digital keypad
module
.
Connnector
GF-1P~4P
1~4-call
button panel
< Direct select >
GF-SW
Call switch module
. Di rec tory card (plate & paper)
. C onnnector
< Audio >
GF-DP
GF-DA
Audio module
.
Connnector
< Video >
GF-VP
GF-VA
Camera module
.
Connnector
GF-2B(3B)
DOORBELL
(option)
.
Packet of screws
.
OPERATION MANUAL
.
See page 4 for compatible
components
GF-MK
GF-MK
on GFW-S
GFW-S
Desktop stand
Two-wire Bus
control unit
.
INSTALLATION
MANUAL
.
Special screwdriver
GF-BC GF-VBC
Video
control unit
GFW-VBC
Expander Video control unit
Use w/
GF-VBC/A
GF-4Z
4-way bus
junction unit
Audio system
< Entrance station >
2-CALL 3-CALL 4-CALL 6-CALL
Audio
section
GF-DA
GF-DP
GF-DA
GF-DP
GF-DA
GF-DP
GF-DA
GF-DP
GF-SW
GF-2P
GF-SW
GF-3P
GF-SW
GF-4P
GF-SWx2
GF-2P, GF-4P
GF-2F
GF-2B
GF-2F
GF-2B
GF-2F
GF-2B
GF-3F
GF-3B
Call switch
section
Front frame
& Back box
Option
8-CALL 10-CALL 30-CALL
Digital name
scrolling system
Audio
section
GF-DA
GF-DP
GF-DA
GF-DP
GF-DA
GF-DP
GF-DA
GF-DP
GF-SWx2
GF-4Px2
GF-SWx3
GF-4Px2, GF-2P
GF-SWx8
GF-4Px7, GF-2P
GF-NS, GF-NSP
GF-10K, GF-10KP
GF-3F
GF-3B
GF-2Fx2
GF-2Bx2
GF-3Fx3
GF-3Bx3
GF-3F
GF-3B
GF-AD, GF-AP
GF-BP
Call switch
section
Front frame
& Back box
Option
2-CALL 3-CALL 4-CALL 6-CALL
Audio/
Camera
section
GF-VA, GF-VP
GF-DA, GF-DP
GF-VA, GF-VP
GF-DA, GF-DP
GF-VA, GF-VP
GF-DA, GF-DP
GF-VA, GF-VP
GF-DA, GF-DP
GF-VA, GF-VP
GF-DA, GF-DP
GF-VA, GF-VP
GF-DA, GF-DP
GF-VA, GF-VP
GF-DA, GF-DP
GF-VA, GF-VP
GF-DA, GF-DP
GF-SW
GF-2P
GF-SW
GF-3P
GF-SW
GF-4P
GF-SWx2
GF-2P, GF-4P
GF-3F
GF-3B
GF-3F
GF-3B
GF-3F
GF-3B
GF-2Fx2
GF-2Bx2
Call switch
section
Front frame
& Back box
Option
8-CALL 10-CALL 30-CALL
Digital name
scrolling system
Audio/
Camera
section
GF-SWx2
GF-4Px2
GF-SWx3
GF-4Px2, GF-2P
GF-SWx8
GF-4Px7, GF-2P
GF-NS, GF-NSP
GF-10K, GF-10KP
GF-2Fx2
GF-2Bx2
GF-3Fx2
GF-3Bx2
GF-3Fx4
GF-3Bx4
GF-2Fx2
GF-2Bx2
GF-AD, GF-AP
GF-BP
Call switch
section
Front frame
& Back box
Option
Video system
< Entrance station >
AIPHONE
AIPHONE
AIPHONE
AIPHONE AIPHONE
AIPHONE
AIPHONE
AIPHONE
AIPHONE AIPHONE
AIPHONE
AIPHONE AIPHONE
AIPHONE
AIPHONE
AIPHONE
17
Utilizing Two-Wire Bus or Two-Pair Common wiring method system can be designed to meet a variety of installations
GF system features two-wire Bus for audio only system and two-pair common for audio/video system. For audio/video systems, there are two
methods of running trunk lines;
(1) Run two single-pair cables from one apartment monitor station to next, and
(2)
Connect 4-way video junction units (GF-4Z's) on trunk lines on each floor, which can accommodate up to four apartment monitor stations.
Apartment stations
Apartment
monitor stations
System Capacity
Audio system
Max. 250 Apartment stations
Audio + Digital name scrolling
#3
MAX. 5
GF-BC
PT
EL
#2
1P
#1
1P
1P
PS
1P
PS
ea.1P
Power supply
for GF-NS
1P
1P
1P
1P
1P
Bus line
Max. 5 Name scroll modules
GF-BC
1P
PS
GF-1D
When Concierge Station is not required
1P
Bus line
Use GF-1D Apartment stations if GF-MK Concierge station is not included.
GF-1D
Audio/Video Bus lines
GF-BC
2
1
6
1P
1P
1P
GF-VBC
3
4
5
1P
1P
1P
1P x 2
(*)Includes power
supply for GF-NS
Entrance stations
MAX. 5
MAX. 6
Video system
Max. 150 Apartment monitor stations
GF-4Z
AUD
IO
Max. 6 x GF-4Z's
(max. 25 Monitors)
V
IDEO
1P x 2
1P x 2
1P x 2
GF-4Z
1P x 2
1P
Doorbell
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
M
M
M
Max. 25 Monitors
AU
DIO
1P x 2
1P x 2
1P x 2
1P x 2
M
VIDEO
M
M
M
M
M
M
M
M
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
GF-1MDK
.
GF-1MDK to GF-1MDK wiring
.
Wiring with GF-4Z's
PS
PS-24ME/A
Standard
Expanded
for VIDEO 2
GFW-VBC
GF-VBC/A
1P
GF-BC
Expanded video system
1P
IN
1 - 5
6 - 11
1P
PS
PS
for VIDEO 1
Employ GFW-VBC Expander video unit when increasing residential trunk lines, or
locating the farthest monitor stations more than 150m away. From GF-VBC video
control unit, up to two GFW-VBC Expander units may be connected in series.
for AUDIO
1P
1P
1P
150m
150m
150m
#1
#2
Video + Digital Name Scrolling
PS-24ME/A
PT
MAX. 5
GF-BC
1P
1P
Power supply for
GF-NS
1P
Bus line
Max. 5 Name scroll modules
GF-VBC
1P
Up to 3 stations on Audio Bus line
#3
1P
GF-BC
M
GF-1MD
1P
1P
When Concierge Station is not required
1P
Audio
Use GF-1MD Apartment
monitor stations instead
of GF-1MDK
Video
GF-VBC
M
GF-1MD
1P
1P
1P
1P
1Px2
1Px2 1Px2
1Px2
1Px2(*)
Do not mix both wiring methods
on a same trunk line.
1P
1P
1P
Max. 3 Entrance stations per Bus line
#3
#4
MAX. 5
GF-BC
GF-MK
on GFW-S
GF-MK
PS
1P
Bus line
(any no.)
1P
PT
1P
#5
1P
#1
1P
#2
1P
1P
1P
1P
1P
GF-1DK
GF-1DK
GF-1DK
GF-1DK
GF-1DK
MAX. 50
MAX. 50
MAX. 50
ea.1P
1P
1P
Max. 100-call direct
select call buttons
at each
entrance
Doorbell
1P
1P
1P
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
1P
1P
1P
1P
indiv.1P
1P
1P
M
M
M
M
M
M
M
M
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
M
M
M
M
M
M
M
M
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
1P
EL
EL
PS PS
PS
1P
PS
1P
1P
PS
PS
PS
PS
PS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aiphone GF Series and is the answer not in the manual?

Aiphone GF Series Specifications

General IconGeneral
Door ReleaseYes
Frequency Response300Hz - 3.4kHz
Wiring2-wire
Power Supply12V DC
ExpansionUp to 3 sub stations
Operating Voltage12V DC
Operating Temperature-10°C to +50°C
Capacity1 master station and up to 3 sub stations