EasyManua.ls Logo

Aiphone JK-DVF-AC - WIRING AND CONNECTIONS; Wiring Distance; Terminal Names

Aiphone JK-DVF-AC
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
EnglishFrançais
Nederlands
Wiring distance
Power supply Diameter Distance
A - 0.65mm(22AWG) 50m(165')
- 1.0mm(18AWG) 100m(330')
B 12 - 18V AC or DC
or less
0.65 - 1.0 mm
(22-18AWG)
100m(330')
18 - 24V AC or DC 0.65 - 1.0 mm
(22-18AWG)
300m(980')
C - 0.65 - 1.0 mm
(22-18AWG)
300m(980')
D - The connection distance will depend on
thespecicationsoftheelectricdoorstrike,
relaysorelectromagneticdoorlocktobe
connected. To determine the operating
range,pleaserefertothespecicationsof
each terminal.
JK-1MDJK-1MED
A
B
2
2
2
2
2
2
2
2
CD
A1
A2
A1
A2
L
L
Master station
Video door station
Video
door
station
Access control keypad
Access
control
keypad
Power supply
Request to exit/entry button
Timer
Relay
Relay
Automatic gate
Electromagnetic
doorlock
Electricdoorstrike
or
Request to exit/entry button
or
or
WIRING AND CONNECTIONS
Outline of connections and wiring distance
Terminal names
(Terminals for Video door station)
(Terminals for Access control keypad)
JK-DVF-AC_ENG.indd 5 2009/10/05 21:18:37