VF Series | Non-Cycling | 10 - 2,000 scfm
DHT Series | High Inlet Temperature | 20 - 125 scfm
AES Series | Energy Saving Digital Scroll | 600 - 10,000 scfm
REFRIGERATED DRYER USER MANUAL
The information in this manual is current as of its publication date and applies to VF, DHT, and AES Series refrigerated air dryers until next revision of this manual.
Copyright © December 2017 Aircel, LLC. All rights reserved.
WARRANTY NOTICE
Failure to follow the instructions
and procedures in this manual, or
misuse of this equipment, will void its
warranty.
WARNING!
Users are required to read the entire
User Manual before handling or using
the product. Keep the User Manual in
a safe place for future reference.

Table of Contents

Questions and Answers

  • A
    Aaron AllenAug 2, 2025
    What to do if my Aircel Dryer system is not working properly and there is water downstream?
    • K
      Kevin MartinezAug 2, 2025
      If your Aircel Dryer system isn't working correctly and there's water downstream, several factors could be at play. The refrigeration compressor might be stopping because of a dirty condenser coil, leading to high pressure, so you should clean the condensing coil and make sure the unit has enough ventilation. Another reason could be the refrigeration compressor cycles on and off and can't keep suction pressure, in that case, inspect the condensing coil for any obstructions. If clear, use refrigerant pressure gauges to see if the unit is low on refrigerant. Also consider the possibility of low refrigerant levels, possibly due to a leak in the air-to-refrigerant side of the heat exchanger, so you should repair or replace the heat exchanger and recharge the system according to specifications.
  • D
    Donna Walker DVMAug 17, 2025
    Why is there water downstream of my Aircel Dryer system or no discharge from the separator/filter?
    • C
      Courtney McclureAug 17, 2025
      There are several reasons why you might find water downstream of your Aircel Dryer system or a lack of discharge from the separator/filter. It could be due to a failed or short-circuited timer on the drain or a failed drain solenoid, in which case you should replace the timer drain. Another cause may be bulk liquid entering the dryer from upstream, so check the drains on the aftercooler or air compressor. Also, verify that the inlet compressed air temperature and CFM flow rate to the dryer do not exceed the dryer's capacity; adjust as needed to meet specifications. A leak in the air-to-air heat exchanger can also cause this issue, requiring replacement of the heat exchanger.

Summary

Safety

Introduction, Signal Words, and General Procedures

Defines signal words and covers general safety practices for dryer operation and maintenance.

Refrigerant Safety and First Aid

Details hazards of refrigerants, including inhalation, skin/eye contact, and first aid.

Lockout Tagout Procedures

Explains the critical steps for implementing lockout/tagout for energy control during service.

Dryer Description

Installation

Maintenance

Filter Element Replacement

Provides instructions for safely replacing filter elements in the dryer system.

Troubleshooting

Introduction and Electrical;Refrigeration Issues

Identifies common problem sources and guides on troubleshooting electrical and refrigeration issues.

Condensate Removal and Other Issues

Addresses problems related to condensate removal, other issues, and troubleshooting guides.

Series Specific Troubleshooting

Offers specific guides for troubleshooting common problems in VF, DHT, and AES series dryers.

Warranty Information