Maintenance
8-38 Flying Cloud
PLACE BREAKER
LABEL HERE.
CIR.#4
CIR.#2
CIR.#3
MAIN
NEUTRAL BUSS
GROUND BUSS
8GA BARE
COPPER
CIR.#1
20
30
CIR.#5
20
20
20
20
Standard 30 Amp Circuit Breaker Layout:
• Circuit 5 - 20 Amp - Water Heater
• Circuit 4 - 20 Amp - GFI Refer, Galley, Bath, Outside,
Dinette Receptacles, Front TV, Living Area
• Circuit 3 - 20 Amp - Microwave Receptacle
• Circuit 2 - 20 Amp - Converter, Bedroom, Blu-Ray
Player Receptacles
• Circuit 1 - 20 Amp - A/C
• Main - 30 Amp
Breaker label content may vary. CSA include 15 Amp
breakers.
Standard 50 Amp Circuit Breaker Layout:
• Circuit 6 - 20 Amp - Converter, Bedroom, Blu-Ray
Player Receptacles
• Circuit 5 - 20 Amp - Microwave Receptacle GFI
Refer, Galley, Bath, Outside, Dinette Receptacles,
Front TV, Living Area
• Main - 50 Amp
• Main - 50 Amp
• Circuit 4 - 20 Amp - Water Heater
• Circuit 3 - 20 Amp - Converter, Bedroom, Blu-Ray
Player Receptacles
• Circuit 2 - 20 Amp - Front A/C
• Circuit 3 - TV, Bath, Galley, Outside, Dinette, TV, GFI
Refer
Breaker label content may vary. CSA include 15 Amp
breakers.