8
Maintenance
Flying Cloud 8-17
6. Turn the pump switch OFF after all water has been
removed from the storage tank.
7. Remove exhaust hose from water pump.
8. Disconnect the water pump inlet connection and
turn the pump on until all the water is expelled.
This water, about 1/2 cup, can be caught in a towel
or rag.
9. Lower the front of the trailer as far as the jack
will allow until water ceases to drain, then crank
the jack up as high as it will go and allow any
remaining water to drain out.
10. After the water has stopped running from the drain
lines, apply at least 60 lb. of air pressure at the city
water inlet. An air-to-city water adapter is available
from your dealer’s RV accessory store. Be sure
the toilet valve, all drain valves, and faucets are
open and pump outlet hose is disconnected. This
can be done at a service station and will force any
remaining water from the water heater and remove
any water that may be trapped in low areas.
11. Pour a cup of non-toxic RV antifreeze that has
been approved and listed by a recognized testing
authority such as Underwriter Lab into the lavatory,
sink and tub drains to prevent trap freeze-up.
cAuTION
Remove all RV antifreeze spillage from all drain
and faucet parts after winterizing. Failure to do so
could result in damage to the plumbing xture’s
nish.
12. Be sure to open the waste-holding tank dump
valves and drain and ush the tanks thoroughly
(this is very important as the sewage in the tanks,
if frozen, could seriously damage the tanks). Plan
ahead and have this done at a dump station.
13. If so equipped, remove the cartridge of the water
purier and leave the purier valve in the open
position.
14. Remove the batteries from your trailer and store
in a cool, dry place where there is no danger of
freezing. It is very important for optimum life of a
battery to check it periodically and to keep it fully
charged.
15. Remove any items (food, cosmetics, etc.) from
trailer interior that might be damaged by freezing,
or that might damage the trailer if containers
should break.
For additional winterizing protection, add a non-toxic
antifreeze (approved for drinking water system) to the
water lines using the following procedure:
1. Reconnect all lines except the hose to the pump
inlet port. Close all drain valves.
2. Turn water heater bypass valve to bypass position.
Refer to Water Heater Bypass Valve illustration.
3. Replace the galley faucet lter with the bypass pipe
(refer to Galley Faucet Filter in the Interior section).
Store lter in a warm place.
4. Attach a length of hose to the pump inlet port. This
piece of hose should be long enough for the free
end to be inserted into and reach the bottom of the
antifreeze container.
5. Dilute the antifreeze solution in accordance with
the manufacturer’s instructions.
6. Open all water faucets.
7. Insert hose length into the antifreeze container,
turn the pump switch on, and run the water pump
until the antifreeze solution lls all water lines.
Flush toilet. Work hand shower spray while holding
down in tub.
8. Shut off the pump and close all faucets.
9. Disconnect the hose length from pump inlet tting
and reconnect water system inlet line.
Water Heater Bypass Valve
1. Water Heater
2. Bypass Valve
If valve is in-line with water line, turn bypass valve
clockwise to close.
Water Heater Bypass Valve Locations
19 ft. Bambi and the 23 ft. Rear Bed - under the corner
bed, accessible from holes in the bed top under the
mattress.
20 ft. - under roadside front dinette seat, remove the
seat cushion and you will see holes in the seat base for
access.