EasyManua.ls Logo

Airwell AWAU-YDV280-H13 User Manual

Airwell AWAU-YDV280-H13
187 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SYJS-
03-2017 REV.A Edition: 2017-03
Service Manual
Flow Logic III

Questions and Answers:

Airwell AWAU-YDV280-H13 Specifications

General IconGeneral
BrandAirwell
ModelAWAU-YDV280-H13
CategoryAir Conditioner
LanguageEnglish

Summary

Specification

Piping diagram

Specific Model Piping Diagrams

Schematic diagrams illustrating piping connections for various outdoor unit models.

Wiring diagram

Capacity calculation due to capacity modification coefficient

Operation range

Installation

9.1 Safety

Crucial safety instructions and warnings to be followed before and during installation.

9.5 Construction of refrigerant pipe

Procedures for determining pipe specifications and restrictions for refrigerant piping.

Trial operation

12.3 Trial operation confirmation

Step-by-step confirmation for trial operation, focusing on wired controller status.

Outdoor control board photo

Outdoor PCB dip switch setting

BM1 Definition

Details functions and settings for BM1 DIP switches related to unit operation.

BM2 Definition

Details functions and settings for BM2 DIP switches, including quiet running and anti-snow.

BM3 Definition

Defines BM3 DIP switch functions for unit type and HP setting.

BM4 Definition

Details BM4 DIP switch functions for quantity lock, drop selection, and protocol.

Outdoor system control function

15.1 Start Control

Explains conditions and procedures for compressor start and protection control.

15.2 Target pressure control

Details target pressure settings for cooling/heating and their impact on compressor frequency.

15.4 Pressure protection control

Explains high and low-pressure protection mechanisms to prevent system damage.

15.5 Overheating protection control

Details protection measures for compressor overheating based on temperature readings.

15.6 Current protection control

Describes how the system manages compressor operating frequency based on current limits.

Failure code

Master unit digital tube display failure code

Lists failure codes displayed on the master unit, their definitions, and descriptions.

Indoor unit LED status

Information on LED status indicators for indoor units and their corresponding failure codes.

Troubleshooting

2. Abnormity detection method

Steps to detect abnormalities, focusing on sensor checks and connections.

3. Abnormity confirmation conditions

Criteria used to confirm an abnormality, based on AD values and operating conditions.

4. Possible causes

Lists potential causes for detected abnormalities, such as sensor issues or connection problems.

APPENDIX Sensor Resistance Table

Related product manuals