REFRIGERANT
R410A
HEAT PUMP
DLS DC Inverter Series
ECO DESIGN
JUNE – 2013
SM DLSDCI 3-A.1 GB
Indoor Units Outdoor Units
DLS 18 DCI YBDE018-H11
DLS 24 DCI YBDE024-H11
DLS 30 DCI YBDE030-H11
DLS 36 DCI
YBD036-H11
YAD036-H13
DLS 43 DCI
YBD042-H11
YAD042-H13

Questions and Answers:

Airwell DLS 30 DCI Specifications

General IconGeneral
TypeInverter
Heating Capacity3.2 kW
SEER6.1
SCOP4.0
RefrigerantR32
Power Supply220-240V/50Hz
Energy Efficiency Ratio (Cooling)3.5
Indoor Unit Weight9 kg
Outdoor Unit Weight32 kg
Operating Temperature (Heating)-15°C to 24°C

Summary

Product Data Sheets for DLS DC Inverter Series

Performance Data and Pressure Curves

5.1 DLS 18 DCI Performance Data

Cooling capacity and pressure curves for DLS 18 DCI.

5.2 DLS 24 DCI Performance Data

Cooling and heating capacity data for DLS 24 DCI.

5.3 DLS 30 DCI Performance Data

Cooling and heating capacity data for DLS 30 DCI.

5.4 DLS 36 DCI Performance Data

Cooling and heating capacity data for DLS 36 DCI.

5.5 DLS 36 DCI Performance Data

Cooling and heating capacity data for DLS 36 DCI.

5.6 DLS 43 DCI Performance Data

Cooling and heating capacity data for DLS 43 DCI.

5.7 DLS 43 DCI Performance Data

Cooling and heating capacity data for DLS 43 DCI.

Sound Level Characteristics

Electrical Data

Wiring Diagrams

9.1 DLS 18 DCI Indoor Unit Wiring

Wiring diagram for the DLS 18 DCI indoor unit.

9.2 DLS 24/30 DCI Indoor Units Wiring

Wiring diagram for the DLS 24 and 30 DCI indoor units.

9.3 DLS 36 DCI Indoor Unit Wiring

Wiring diagram for the DLS 36 DCI indoor unit.

9.4 DLS 43 DCI Indoor Unit Wiring

Wiring diagram for the DLS 43 DCI indoor unit.

9.5 Outdoor Units Wiring (YBDE 018/024-H11)

Wiring diagram for YBDE 018/024-H11 outdoor units.

9.6 Outdoor Unit Wiring (YBDE 030-H11)

Wiring diagram for the YBDE 030-H11 outdoor unit.

9.7 Outdoor Unit Wiring (YBD036-H11)

Wiring diagram for the YBD036-H11 outdoor unit.

9.8 Outdoor Unit Wiring (YBD042-H11)

Wiring diagram for the YBD042-H11 outdoor unit.

9.9 Outdoor Unit Wiring (YAD036/042-H13)

Wiring diagram for the YAD036/042-H13 outdoor units.

9.10 1PH Indoor Power Supply Wiring (DLS 18)

Power supply wiring diagram for DLS 18 indoor unit.

9.11 1PH Outdoor Power Supply Wiring (DLS 18,24)

Power supply wiring diagram to outdoor unit for DLS 18, 24.

9.12 1PH Outdoor Power Supply Wiring (DLS 30)

Power supply wiring diagram to outdoor unit for DLS 30.

9.13 1PH Outdoor Power Supply Wiring (10.0-14.0 kW)

Power supply wiring diagram to outdoor unit for 1PH units (10.0-14.0 kW).

9.14 1PH Separate Power Supply Wiring

Separate power supply wiring diagram for 1PH units (10.0-14.0 kW).

9.15 3PH Outdoor Unit Power Supply Wiring

Power supply wiring diagram for 3PH units to the outdoor unit.

9.16 3PH Separate Power Supply Wiring

Separate power supply wiring diagram for 3PH units.

Refrigeration Diagrams

10.1 Heat Pump Models Refrigeration Diagram

General refrigeration flow diagram for heat pump models.

Control System Overview

12.2.3 Control Features Overview

Details on compressor, fan, RV, EEV, HMI, dry contacts, and sensors.

12.3.2 Communication and Failures

Details on indoor unit communication and fault definitions.

12.3.4 Temperature Measurements

Information on thermistor default values and fault detection.

12.4 Indoor Unit Control Functions

General control functions for the indoor unit, including load calculation.

12.4.3 Cooling Mode Operations

General definition, control functions, and sequence diagrams for Cooling mode.

12.4.4 Heating Mode Operations

General definition, control functions, and sequence diagrams for Heating mode.

12.4.6 Dry Mode Operations

General definition, control functions, and sequence diagrams for Dry mode.

12.5.2 Compressor Operation and Speed Control

Details on compressor operation, speed limits, and shutdown cases.

12.5.3 EEV Control Functions

General rules, operation range, and initial value determination for EEV control.

12.6 Protections Overview

Covers thermodynamic protections for IDU and ODU units.

12.6.3 Deicing Procedures

Details on deicing starting conditions and protection procedures.

12.6.4 High/Low Pressure Protection

Details on high and low pressure protection mechanisms and fault codes.

12.7 Technician Test Mode Operations

Instructions for entering, performing, and exiting the technician test mode.

12.8.4 Technician Peripheral Test (TPT)

Information on the technician peripheral test mode.

12.8.4.3 - 12.8.4.8 Test Procedures

Procedures for Pump Down, OFAN, EEV, Compressor, RV, and Sensor tests.

12.9 Jumper/DIP-Switch Settings

Configuration settings using jumpers and DIP switches for IDU and ODU.

12.10 System Parameters Overview

General and model-dependent system parameters with default values.

Troubleshooting and Corrective Actions

13.1 Safety Precautions for Electrical Assemblies

Covers high voltage, charged capacitors, and advisory notes for safe handling.

13.2 General System Failures and Corrective Actions

Lists common indoor and outdoor unit failures and their solutions.

13.3 Refrigeration System Checks

Procedures for checking system pressures and thermodynamic measures.

13.4 Troubleshooting by Diagnostics Codes

Guide to using diagnostic codes for troubleshooting outdoor and indoor units.

13.4.2 Outdoor Unit Diagnostics and Actions

Detailed diagnostic codes and corrective actions for outdoor unit issues.

13.4.4 Indoor Unit Diagnostics and Actions

Detailed diagnostic codes and corrective actions for indoor unit issues.

13.5 Procedures for Checking Main Parts

Step-by-step procedures for checking key components like voltage, filters, and drivers.

13.5.4 Compressor Driver Checks by Model

Specific checks for compressor drivers based on different outdoor unit models.

13.5.9 Compressor Checks

Procedure to check compressor connections, phase resistance, and current.

13.5.16 Indoor-Outdoor Unit Communications Checks

Procedure to check voltage on interconnection wiring for communication.

Servicing Procedures

14.1 Outdoor Unit Servicing (DLS 36/43)

Procedures for servicing the DLS 36/43 outdoor units.

14.1.9 Removing Refrigeration Parts

Steps for removing refrigeration components like valves and switches.

14.1.10 Removing the Compressor

Steps for removing the compressor, including refrigerant evacuation.