RESIDENTIAL SALT WATER CHLORINE GENERATOR
Classic Series
INSTRUCTION MANUAL
This manual is for:
CLASSIC RP MODEL RANGE
FEATURING REVERSE POLARITY TECHNOLOGY
RP-15, RP-20, RP-25, RP-36, RP-50, RP-64, RP-80
CLASSIC LS MODEL RANGE
(RP20-3500ppm, RP25-3500ppm, RP35-3500ppm)
MIDI RANGE
(RP-100, RP-150)
Includes:
TIME CLOCK MODELS (battery backup optional)
POOL LIGHT MODELS (where fi tted)

Questions and Answers

  • J
    Jacob RobinsonAug 13, 2025
    Why is my AIS Water Filtration System chlorine generator not producing enough chlorine?
    • M
      Mason CraigAug 14, 2025
      If your AIS Water Filtration System's chlorine generator isn't producing enough chlorine, there are several potential causes. First, the chlorine production level might be set too low; try adjusting the control knob clockwise to increase production. Second, the generator may not be running for a sufficient amount of time; increase the operation running time. A calcified electrode can also reduce chlorine output, so you should clean the electrode. Finally, incorrect water chemistry can impact chlorine generation, so ensure your water chemistry is properly balanced.
  • S
    Samuel WeaverAug 17, 2025
    What to do if the low salinity light is on or flashing on my AIS Water Filtration System?
    • T
      Todd GreenAug 17, 2025
      If the low salinity light is flashing on your AIS Water Filtration System, it typically indicates that the water salinity is too low. Have the salinity level tested by a pool professional and increase it if necessary. Another possible cause is a calcified electrode, which requires cleaning. A faulty electrode may also be the reason, so have it tested and replaced if necessary.
  • J
    Jeremy AndersonAug 21, 2025
    Why are there no lights on my AIS Water Filtration System chlorine generator and the pump is not running?
    • B
      Brian RamosAug 21, 2025
      If there are no lights on your AIS Water Filtration System's chlorine generator and the pump isn't running, the first thing to check is the power supply. Unplug the chlorine generator from the power and test the outlet with another working appliance to ensure there is power. Another possibility is that the time clock is in a designated off period, or the switch is in the OFF position; switch to BYPASS to circumvent TIMER or OFF functions.
  • D
    David JohnsonAug 25, 2025
    What to do if Status Light (3) is flashing and the generator is beeping on my AIS Water Filtration System?
    • T
      Timothy DavenportAug 26, 2025
      If Status Light (3) is flashing and the generator is beeping on your AIS Water Filtration System, it could be due to a few reasons. One possibility is that the pump isn't running, the filtration is blocked, or there's an air lock. A large air bubble in the electrode housing can trigger this alarm, so clean out the skimmer box, check and clear any blockages, and re-prime the pump. Another potential cause is that the electrode lead isn't properly plugged in; double-check that the electrode lead plug is securely connected to the electrode.
  • T
    Timothy FlowersAug 28, 2025
    Why is the high salinity light on or flashing on my AIS Water Filtration System?
    • M
      Marissa KimAug 28, 2025
      If the high salinity light is on or flashing on your AIS Water Filtration System, it typically means the pool salinity is too high. Have the salinity level tested by a pool professional and decrease it if necessary. If the salinity level is within the correct range, the chlorine generator may be faulty. In this case, contact your dealer or AIS Water for assistance.
  • N
    Nicholas JacksonSep 1, 2025
    Why is the circuit breaker tripping on my AIS Water Filtration System?
    • S
      Shannon CampbellSep 1, 2025
      If the circuit breaker is tripping for your AIS Water Filtration System, it could be due to several reasons. A mains power surge may be the cause; set the machine to off and push the circuit breaker. A fault with shorted electrodes could also be the problem; visually inspect the electrode and check for foreign or conductive surfaces. If found, remove and clean the cell. If neither of these resolves the issue, there may be a fault with the power supply, in which case you should contact your dealer or AIS Water.
  • K
    Kimberly RangelSep 5, 2025
    Why is Status Light (3) on and the pump is running, but no other lights are on, on my AIS Water Filtration System?
    • N
      natashawoodSep 5, 2025
      If Status Light (3) is on and the pump is running, but no other lights are on, on your AIS Water Filtration System, it could mean that the chlorine generator production is turned off. To resolve this, adjust the control knob clockwise to increase production.
  • D
    Daniel OchoaSep 9, 2025
    What causes white powdery material on the pool bottom with my AIS AutoChlor RP-50 Water Filtration Systems?
    • R
      Rodney RileySep 9, 2025
      If you notice a white powdery material on the bottom of your pool when using the AIS Water Filtration System, it's likely due to excessive water hardness. Test the water chemistry and adjust accordingly to resolve this issue.

Summary

AutoChlor Classic Series Manual Scope

Product Model Ranges

Covers RP, LS, and MIDI models of the AutoChlor Classic Series.

Control Panel and Component Identification

Indicator Lights

Describes warning lights for salt, power, flow, and operation status.

Key Controls and Features

Details the chlorine controller, output indicator, circuit breaker, and timers.

Introduction to the AutoChlor System

Addition of Salt Guide

Explains how to calculate and add salt, with an example.

Chlorinator Cell Housing Installation

Plumbing Placement Guidelines

Advises on integration with heaters and solar systems.

Power Supply Installation and Mounting

Power Supply Operational Functions

Pump Output Socket Functionality

Explains the socket for powering the pool pump.

Understanding Warning Indicator Lights

Orange Indicator Lights

Covers high salt, standby, and low salt/clean cell conditions.

Red Indicator Lights

Describes power on, no water flow, and overload conditions.

Advanced Indicator Lights and RP Model Notes

Red Indicator Light Details

Explains overload and normal operation (forward/reverse) states.

Detailed Control and Timer Operations

Chlorine Controller Adjustment

How to set the chlorine output level.

RP Model Specific Operation Details

Reverse Polarity Cycle Explained

How the 8-hour cycle cleans electrodes.

Electrode Maintenance Procedures

Step-by-Step Electrode Removal

Guide for safely removing the electrode.

Electrode Cleaning and Reassembly

Electrode Cleaning Process

Instructions for cleaning with acid solution.

Troubleshooting Guide: Common Issues

Flashing Light and Beeping Alarm

Troubleshoots the flashing status light and alarm.

Troubleshooting Guide: Salinity and Breakers

Circuit Breaker Tripping Causes

Addresses issues causing the circuit breaker to trip.