il.
MEASURING
METHOD
1.
TAPE
SPEED
DEVIATION
Frequency
Counter
Line
GXC-75D
Output
Input
Fig.
2
As
shown
in
Fig.
2
connect
a
Frequency
Counter
to
the
Line
Output
of
Model
GXC-75D.
Playback
a
1,000
Hz
pre-recorded
test'tape.
Take
a
Frequency
Counter
reading
at
the
biginning,
middle,
and
end
of
tape
winding
during
playback,
and
obtain
the
tape
speed
deviation
from
the
following.
formula.
TAPE
SPEED
DEVIATION
(%)
=
Frequency
counter
reading
(Hz)
-
1,000
Hz
1,000
Hz
sa
2.
WOW
AND
FLUTTER
Line
input
W
d
GXC-75D
(Output
ne
Aine
aces
Fig.
3
Method
A
As
shown
in
Fig.
3,
connect
a
Wow
and
Flutter
Meter
to
the
Line
Output
of
Model
GXC-75D.
Playback
a
3,000
Hz
pre-reocrded
test
tape
and
take
a
Wow
and
Flutter
reading
at
the
beginning,
middle,
and
end
of
tape
winding
during
playback.
The
maximum
value
of
these
respective
readings
will
represent
the
Wow
and
Flutter.
Method
B
Supply
a
3,000
Hz
sine
wave
signal
from
an
Audio
Frequency
Oscillator
and
make
a
recording
on
a
blank
tape
at
the
beginning;
middle,
and
end
of
tape
winding.
Rewind
and
playback
the
resultant
signal.
Measure
Wow
and
Flutter
with
a
Wow
and
Flutter
Meter,
(The
Wow
and
Flutter
value
of
method
B
will
be
close
to
\/2
times
of
method
A.)
3.
FREQUENCY
RESPONSE
Audio
Frequency
Oscillator
output
input
GXC-75D
High
Sensitivity
V.T.V.M.
Fig.
4
For
measuring
Frequency
Response,
connect
instru-
ments
as
shown
in
Fig.
4
and
proceed
as
follows.
1)
Supply
a
1,000
Hz
sine
wave
signal
to
the
Line
Input
of
Model
GXC-75D
from
an
Audio
Frequ-
ency
Oscillator
through
an
Attenuator.
2)
Set
Deck
to
recording
mode
and
turn
recording
level
control
to
maximum.
Adjust
Attenuator
to
obtain
a
0
dBm
High
Sensitivity
V.T.V.M.
reading.
3)
Under
conditions
described
in
2)
above,
readjust
Attenuator
so
that
the
Line
Output
is
-20
dBm,
and
record
50
to
13,000
Hz
spot
frequencies.
4)
Take
High
Sensitivity
V.T.V.M.
spot
frequency
readings
and
plot
the
values
on
a
graph.
NOTE:
When
measuring
Frequency
Response,
new
tape
should
be
used.
4.
SIGNAL
TO
NOISE
RATIO
7
aoe
GXC-75D
output
mput
High
Sensitivity
|
V.T.V.M.
Fig.
5
As
shown
in
Fig.
5,
connect
a
High
Sensitivity
V.T.V.M.
to
the
Line
Output
of
Model
GXC-75D.
Playback
a
250
Hz
OVU
pre-recorded
test
tape
and
measure
the
output
level.
Then
remove
the
tape
and
measure
the
noise
level
under
the
same
condition.
Convert
each
of
the
measured
values