Colour: White to RAL 90 Internal Building use only
Patent GB 2375479
Installer: Please ensure that this information is left
with the end user of this pr
oduct.
Assembled
Remove
for cleaning
ALWAYS read the installation instructions before installing
this product.
ALWAYS read the installation and end user care instructions.
ALWAYS match the correct waste to the shower base.
ALWAYS have the pumped waste installed by a trained
and experienced skilled craftsman.
NEVER use the pumped waste without the unit fully
assembled.
BEWARE A child finger trap may be present during the
handling or use of this product.
ALWAYS Keep fingers clear of the gaps between the cover,
and the locking ring.
DO NOT place matches or cigarettes on or near this product.
The following plastic materials are used in this
product: Acrylonitrile Butadiene Styrene (ABS),
Ethylene Propylene Thermoplastic Rubber (EPTR)
© 2007 AKW Medi-Care Limited 05-017-008-03
For further details on this and other AKW products please contact your distributor
- see details on outer packaging
The measurements throughout these installation and user care instructions have been converted from metric to its equivalent in imperial, therefore all
dimensions are approximate and subject to manufacturing tolerances. AKW MediCare does not make any warranty, expressed or implied, or accept any
liability in connection with this information or its use. This information is furnished upon the condition that the person receiving it shall make his/her own
tests to determine the suitability ther
eof for his/her particular purpose.
*John Guest and Speedfit are registered trade marks of John Guest International Limited
*Polypipe is a registered trademark of Polypipe plc, a subsidiary of IMI plc
15mm or 22mm PW50 Pumped Waste
Installation and user care instructions
AKW MediCare
Question and Answer IconNeed help?

Do you have a question about the Akw MediCare and is the answer not in the manual?

Summary

Pre-Installation and Safety Guidelines

Installation Prerequisites and Safety

Essential steps before installation, including reading instructions, matching components, skilled installation, and safety warnings.

Product Identification and Usage Notes

Details on product materials, color, patent, and specific usage instructions for installers.

Installation and User Care

Installation Instructions

Step-by-step guide for fitting the pumped waste unit, including pipe connection and assembly.

User Care and Maintenance

Guidance on keeping the pumped waste clean, including disassembly, cleaning procedures, and disinfection.

Packaging Information

Details on product packaging materials and their suitability for recycling.

Overview

This document describes the AKW MediCare 15mm or 22mm PW50 Pumped Waste, an essential component for shower installations, particularly in environments requiring reliable and low-maintenance waste management. The manual provides comprehensive installation and user care instructions, ensuring proper setup and prolonged product life.

Function Description

The AKW MediCare PW50 Pumped Waste is designed to efficiently remove water from a shower base, directing it to a pump. It is engineered for use with either 15mm or 22mm Polypipe* or equivalent plumbing systems. The device ensures proper drainage and prevents water accumulation in the shower area. Its design incorporates a trap mechanism to prevent odors and a removable grid and cover for easy cleaning and maintenance. The "pumped waste" designation implies it is intended to work in conjunction with a pump system, which is crucial for installations where gravity drainage is not feasible or sufficient.

Important Technical Specifications

  • Pipe Compatibility: Designed for use with ø15mm or ø22mm Polypipe* or equivalent (not supplied).
  • Materials: The product utilizes several plastic materials for its construction:
    • Acrylonitrile Butadiene Styrene (ABS): Used for components like the main body and visible parts, offering durability and aesthetic appeal. The sectioned view explicitly labels components made of ABS.
    • Ethylene Propylene Thermoplastic Rubber (EPTR): Likely used for seals and gaskets, providing flexibility and water-tightness.
    • Polypropylene (PP): Used for packaging, indicating its recyclability.
  • Color: White to RAL 90, ensuring a clean and standard appearance that blends with most bathroom aesthetics.
  • Patent: Protected by Patent GB 2375479, indicating unique design and engineering.
  • Intended Use: Internal Building use only.
  • Components: The device comprises several key parts:
    1. Main body: The core structure of the waste.
    2. JG adaptor locking ring: Secures the pipe connection.
    3. Main body seal: Ensures a watertight connection between the waste and the shower base.
    4. Clamping ring: Tightens the waste assembly to the shower base.
    5. Grid: Prevents large debris from entering the waste, removable for cleaning.
    6. Cover: Protects the internal components and provides a finished look, also removable for cleaning.
    7. Shower base area: The surface from which water is drained.

Usage Features

  • Ease of Installation: The instructions emphasize a straightforward installation process, requiring the deburred end of the pipe to be firmly pushed into position and the JG adaptor locking ring to be fitted. The waste is then located, ensuring the main body seal is in contact with the underside of the shower base, followed by the clamping ring, grid, and cover.
  • Secure Fit: The clamping ring is tightened clockwise to secure the waste to the shower base, ensuring a stable and leak-free installation.
  • Matching: Users are advised to "ALWAYS match the correct waste to the shower base," highlighting the importance of compatibility for optimal performance.
  • Professional Installation Recommended: The manual states to "ALWAYS have the pumped waste installed by a trained and experienced skilled craftsman," underscoring the need for expertise to ensure correct and safe installation.
  • Full Assembly Requirement: It is crucial to "NEVER use the pumped waste without the unit fully assembled," to ensure proper function and safety.
  • Child Safety: A "BEWARE A child finger trap may be present during the handling or use of this product" warning is included, along with advice to "ALWAYS Keep fingers clear of the gaps between the cover, and the locking ring," indicating a focus on user safety.
  • No Flammable Materials: Users are instructed to "DO NOT place matches or cigarettes on or near this product," to prevent potential hazards.

Maintenance Features

  • Low Maintenance Design: AKW pumped wastes are designed for "low maintenance and reliable operation."
  • Periodic Cleaning: The product should be "cleaned periodically to remove any accumulation of hair or other detritus, using normal domestic bathroom cleaning materials." This is a key aspect of maintaining hygiene and preventing blockages.
  • Easy Access for Cleaning: The design allows for easy disassembly to clean the trap. The cover (7) is removed by rotating anti-clockwise, the grid (6) is lifted vertically by gripping the centre peg, and the trap can then be accessed. Reinstallation is done by reversing these steps.
  • Disinfection Guidelines: Where disinfection is necessary, "standard established procedures for disinfecting equipment should be used," with a caution to consider the effects of aggressive chemicals on plastics.
  • Flushing After Cleaning: After cleaning, it is recommended to "always flush down with water then wipe thoroughly with a damp cloth to remove any cleaning material residues before drying off."
  • Chemical Compatibility: Users are warned not to "use strong or concentrated acidic, alkaline or other cleaning materials as these may discolour or otherwise damage the product." This is vital for preserving the integrity and appearance of the plastic components.
  • Autoclave Cleaning Not Approved: AKW "do not approve or recommend autoclave cleaning of any of the components due to the damage this can cause to the special engineering plastics used in the construction of this product," indicating specific material limitations.
  • Planned Maintenance: The pumped waste "should be checked as part of a planned maintenance programme, retightening the screws as required and any part showing evidence of damage or misuse must be replaced." This proactive approach ensures long-term reliability.

Packaging and Environmental Considerations

  • Protective Packaging: The waste is supplied in a polypropylene (PP) bag to keep it unsoiled until installation and may also be packed in a cardboard box.
  • Recyclability: Both the PP bag and cardboard box are "suitable for recycling operations and should be disposed of in accordance with local recycling regulations," demonstrating the manufacturer's commitment to environmental responsibility.

In summary, the AKW MediCare PW50 Pumped Waste is a robust, user-friendly, and maintainable solution for shower drainage, designed with attention to safety, durability, and environmental considerations. Its clear instructions ensure that both installers and end-users can manage the product effectively throughout its lifespan.