Type Message Location Additional Information Action
33 KEY REDUCED
The features normally asso-
ciated with the active key
have been reduced due to a
hardware problem (CPU
type, insufficient memory,
etc).
CPU (80) INFO 0 = reduced feature set index
- 01 : VMU storage capacity dimin-
ished
- 02 : number of VMU and Auto-
mated Attendant ports diminished
- 03 : Automated Attendant unavail-
able
- 04 : Audiotex unavailable
- 05 : welcome messages unavail-
able
- 06 : distribution list names unavail-
able
- 07 : recording of conversations un-
available
- 08 : duration of please-wait mes-
sage diminished
- 10 : number of NMC metering
statements diminished
- 12 : number of languages dimin-
ished
37 eMMC in MSDB is ap-
proaching its end of life due
to increase in block erase
count / bad blocks
MAIN_CPU_SL
OT
INFO 0 = Indication of MSDB health
status:
- 01: device has reached >= 80% of
its life time due to increased block
erase count
- 02: device has reached > =90% of
its life time due to increased block
erase count
- 03: device has reached >=80% of
its life time due to increased bad
block
- 04: device has reached >=90% of
its life time due to increased bad
block
Replace the
MSDB
38 Power CPU EE does not
support RAM less than 512
MB
MAIN_CPU_SL
OT
INFO 0 = High byte of detected RAM
size
INFO 1= Low byte of detected RAM
size
Example:
comp_info: 01 00 FF FF
The detected RAM size is 256 MB.
Replace the
RAM
50 ISDN ACCESS REBOOT
PROBLEM
Board location.
Interface mark-
er
INFO 0 = D-channel
Chapter